Crucial safety advisory regarding qualified personnel and hazards.
Definitions and explanation of safety advisories used throughout the manual.
Discussion on refrigerants affecting the ozone layer and responsible handling.
Emphasizes technician certification and compliance with refrigerant handling laws.
Warning about hazards and requirements for qualified personnel performing field wiring.
Mandates the use of proper PPE to protect against electrical, mechanical, and chemical hazards.
Adherence to company environmental, health, and safety policies for hazardous work.
Information on document ownership, usage restrictions, and referenced trademarks.
List of changes and updates made to the document across different versions.
Detailed breakdown of alphanumeric codes identifying unit type, components, and options.
Lists electrical, environmental, mounting, and physical specifications for the purge unit.
Critical safety warning about potential injury from improper service procedures.
Guidance on locating and using information from the unit's nameplate for inquiries.
Details of items included in the EarthWise purge conversion kit.
List of components the installer must provide for the conversion package.
Information on an optional kit and its compatible refrigerant parts.
Steps for verifying the correct package was shipped and inspecting for damage.
Procedures for disconnecting and removing the existing purge system from the chiller.
Detailed steps for removing the unit, including electrical, water, and refrigerant connections.
Warning about using proper lifting equipment and potential for injury or damage.
Instructions for installing the new EarthWise purge, including wiring and hardware changes.
Overview of EarthWise purge design for low-pressure centrifugal chillers.
Guidelines for positioning the purge assembly above the chiller condenser liquid level.
Caution regarding R-11 refrigerant configuration with DynaView to prevent damage.
Steps for mounting the purge assembly to the chiller condenser using brackets.
How to manually set the refrigerant type via the DynaView human interface.
Instructions for inserting the temperature probe into the thermal well with thermal grease.
Requirements for connecting power and the chiller RUN signal to the purge unit.
Details on connecting the 115 Vac main hot line and power supply terminations.
How to supply the 115 Vac chiller run signal to the unit for operation.
Guidelines for remotely mounting and wiring the DynaView human interface.
Connecting to module 3A3 to remotely enunciate fault conditions.
Guidelines for vapor line construction, pitch, slope, and bends for proper drainage.
Connecting the carbon regeneration line to the evaporator and maintaining slope.
Achieving proper liquid refrigerant return by matching condenser and return line pressures.
Recommended steps for making refrigerant line connections to the condenser.
Special considerations for applying the purge to heat recovery or auxiliary condenser units.
Mounting requirements and line connections for purge units with auxiliary/heat recovery condensers.
Installing the separator below the chiller condenser liquid level for alternative mounting.
Connecting the purge liquid separator to suction gas line and sight glass.
Checking the moisture sight glass and changing the filter drier as needed.