8-2. CAPACITY AND THE INPUT CURVES
Indoor air Wet-bulb temperature
difference (°F)
15 class
06 class
12 class
09 class
Indoor air Wet-bulb temperature
difference (°F)
15 class
06 class
12 class
09 class
26.1
24.3
22.5
20.5
18.5
16.6
14.8
13.0
11.0
9.2
7.4
36.7
34.0
31.3
28.8
25.7
23.2
20.7
18.0
15.3
13.0
10.3
48.2
44.8
41.4
38.0
34.0
30.6
27.2
24.1
20.2
17.1
13.5
52.8
49.1
45.4
41.6
37.4
33.7
29.9
26.5
22.1
18.7
14.8
24.3
22.5
20.5
18.5
16.6
14.8
13.0
11.0
9.2
7.4
34.0
31.3
28.8
25.7
23.2
20.7
18.0
15.3
13.0
10.3
44.8
41.4
38.0
34.0
30.6
27.2
24.1
20.2
17.1
13.5
49.1
45.4
41.6
37.4
33.7
29.9
26.5
22.1
18.7
14.8
68
79
59
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
3 7 11 15 19 23 27 31 35 39 43 47 51 55 59 63
Capacity correction factors
Outdoor intake air Wet-bulb temperature (°F)
Heating capacity
68
59
79
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
3 7 11 15 19 23 27 31 35 39 43 47 51 55 59 63
Input correction factors
Outdoor intake air Wet-bulb temperature (°F)
Total input (Heating)
Indoor intake air Dry-bulb temperature (°F)
Indoor intake air Dry-bulb temperature (°F)
Indoor air Wet-bulb temperature
difference (°F)
15 class
06 class
12 class
09 class
difference (°F)
6.8
6.2
5.7
5.1
4.6
4.1
3.6
9.6
8.8
8.0
7.2
6.5
5.8
5.1
11.7
10.7
9.7
8.7
7.8
6.9
6.0
11.4
10.5
9.5
8.5
7.6
6.7
5.8
6.8
6.2
5.7
5.1
4.6
4.1
3.6
3.1
2.6
2.1
9.6
8.8
8.0
7.2
6.5
5.8
5.1
4.4
3.7
3.0
11.7
10.7
9.7
8.7
7.8
6.9
6.0
5.1
4.2
3.3
11.4
10.5
9.5
8.5
7.6
6.7
5.8
4.9
4.0
3.1
67
64
68
75
72
79
60
0.7
0.8
0.9
1.0
1.1
1.2
1.3
14 24 34 44 54 64 74 84 94 104 114
Capacity correction factors
Outdoor intake air Dry-bulb temperature (°F)
Cooling capacity
Indoor intake air Wet-bulb temperature (°F)
72
75
68
64
67
60
79
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
14 24 34 44 54 64 74 84 94 104 114
Input correction factors
Outdoor intake air Dry-bulb temperature (°F)
Total input (Cooling)
Indoor intake air Wet-bulb temperature (°F)