Trane Relay Panel - Section 5. Field Wiring Diagrams

Trane Relay Panel
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 18-HD68D1-3
DUAL FUEL
R
G
Y1
W1
B
24VAC HOT
24VAC
common
RELAY
PANEL
FAN
SOV
DATA
COOL/HEAT -
1st STAGE
HEATING -
3rd STAGE
HEATING -
4th STAGE
W2
O
R
G
W2
Y1/
Y
LO
Y1
B
ONE OR TWO STAGE
HEAT PUMP
D
W1
TWO STAGE
VARIABLE SPEED
GAS FURNACE
B
C
W3
Y2
COOL/HEAT
-2nd STAGE
BK
VS MODE -fan
Y/
Y2
Y2
BK
THERMOSTAT
R
B
D
O
O
R
X2
Note: Enable "BK" (turn on dehumidifier switch or cut “BK” jumper).
Note: Dual fuel switch on Relay Panel must be set to DUAL.
Note: Blower delay profiles must be turned off. See indoor unit
service facts for details.
REMOTE
INDOOR
SENSOR
RS
RS
I D
SENSOR
OUTDOOR
SENSOR
ODT
ODT
O D
SENSOR
DUAL FUEL NON-VARIABLE SPEED GAS FURNACE
THERMOSTAT
R
B
D
Note: Dual fuel switch on Relay Panel must be set to DUAL.
R
G
Y1
W1
B
24VAC HOT
24VAC
common
FAN
SOV
DATA
COOL/HEAT -
1st STAGE
HEATING -
2nd STAGE
HEATING -
3rd STAGE
W2
O
W3
Y2
BK
R
G
W/
W1
W2
Y
Y
B
SINGLE STAGE
HEAT PUMP
O
R
NON-V.S. ONE
OR TWO STAGE
GAS FURNACE
B
C
X2
D
RELAY
PANEL
REMOTE
INDOOR
SENSOR
RS
RS
I D
SENSOR
OUTDOOR
SENSOR
ODT
ODT
O D
SENSOR
R
G
Y1
W1
B
24VAC HOT
RELAY
PANEL
24VAC
common
DU
AL FUEL WITH NON-VARIABLE SPEED OIL FURNACE
FAN
SOV
DATA
COOL/HEAT -
1st STAGE
HEATING -
2nd STAGE
HEATING -
3rd STAGE
W2
O
R
G
Y
Y
B
SINGLE STAGE
HEAT PUMP
NON-VARIABLE
SPEED
OIL FURNACE
B
C
W3
Y2
BK
R1
Note: Dual fuel switch on Relay Panel must be set to DUAL.
Note: BT (Bonnet Thermostat) model THT1248 (BAYSEN03ATEMPAA)
required for dual fuel, oil furnace applications.
W/
W1
R
O
OIL BURNER PRIMARY
T
T
R1
BT
X2
D
THERMOSTAT
R
B
D
REMOTE
INDOOR
SENSOR
RS
RS
I D
SENSOR
OUTDOOR
SENSOR
ODT
ODT
O D
SENSOR
R
G
Y1
W1
W1
B
24VAC HOT
COOL/HEAT
2nd STAGE
24VAC
common
VS MODE -fan
DUAL FUEL WITH
VARIABLE SPEED OIL FURNACE
FAN
SOV
DATA
COOL/HEAT -
1st STAGE
HEATING -
3rd STAGE
HEATING -
4th STAGE
W2
O
R
G
Y
LO
Y1
B
BK
VARIABLE
SPEED
OIL FURNACE
B
C
W3
Y2 Y
Y2
BK
R1
Note: Remove the "R" to "BK" jumper at the low voltage control board.
Note: Cut the factory installed "R" to "O" jumper at the LVTB.
Note: Blower delay profiles must be turned off. See indoor unit
service facts for details.
Note: Dual fuel switch on Relay Panel must be set to DUAL.
Note: BT (Bonnet Thermostat) model THT1248 (BAYSEN03ATEMPAA)
required for dual fuel, oil furnace applications.
R
O
O
ONE OR TWO
STAGE HEAT PUMP
OIL BURNER PRIMARY
T
T
R1
BT
X2
RELAY
PANEL
D
THERMOSTAT
R
B
D
REMOTE
INDOOR
SENSOR
RS
RS
I D
SENSOR
OUTDOOR
SENSOR
ODT
ODT
O D
SENSOR
Section 5. Field Wiring Diagrams