74
S8V2-SVX001-1A-EN
NO
DEFINITION:
This fault is generated when the HP of
the blower motor does not match the
value that is programmed on the IFC
13 Fault Code
Disconnect electrical
power to funace.
Does the model &
serial number seen on
the mobile link app
match the nameplate?
YES
Verify the motor HP
is correct and the
motor manufacturer
is an authorized
replacement part
Using the link app,
select the correct
model number and
enter the correct
serial number
NO
DEFINITION
This fault is generated when a file
corrup"on error is detected.
14 Fault Code
Turn power off to the
furnace for one minute.
Reapply power
Does E14 error
clear?
YES
Verify opera"on
Replace IFC