Table 7. Supply Duct Connections
Upflow Furnace with Coil
1. Bend furnace flanges up.
2. Set the coil on top of the furnace.
3. Screw through the coil cabinet into the furnace flange. Guide
holes are located on the coil.
Note: There are no longer guide holes located on the furnace flange.
4. Seal per local codes and requirements.
Furnace in Horizontal Left with Coil
1. Bend furnace flanges up.
2. Support the furnace and coil independently.
3. Screw through the coil cabinet into the furnace flange. Guide
holes are located on the coil.
Note: There are no longer guide holes located on the furnace flange.
4. Seal per local codes and requirements.
FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn