EasyManua.ls Logo

Trane TDX060R936V - General Data Specifications

Trane TDX060R936V
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 22-1706-01-0400 (EN)
General
Data
TDX-R-V PRODUCT SPECIFICATIONS1
1 Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories.
2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
3 Based on U.S. Government Standard Tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODEL
RATINGS
2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
3
AFUE (ICS)
Temp. Rise (Min.-Max.) °F.
BLOWER DRIVE
Dia.-Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts/Ph/Hz
COMBUSTION FAN - TYPE
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
FL Amps
FILTER Furnished?
Type Recommended
Filter (No.-Size-Thk.)
VENT Size (In.)
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ORIFICES Main
Nat. Gas. Qty. Drill Size
L.P. Gas Qty. Drill Size
GAS VALVE
DIRECT IGNITION DEVICE
Type
BURNERS Type
Number
POWER CONN. V/Ph/Hz
4
Ampacity (In Amps)
Fuse Size Max. (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
TDX060R936V
39000
36000
60000
55000
92.0
35 - 65
DIRECT
10 x 8
1
4
SEE FAN PERF. TABLE
1/3
1075
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
2 - 14 X 20 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
3 - 45
3 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
4
115/1/60
9.1
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
155/145
TDX080R942V
52000
48000
80000
74000
92.5
35 - 65
DIRECT
11 x 8
1
4
SEE FAN PERF. TABLE
1/2
1075
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
2 - 14 X 20 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
4 - 45
4 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
4
115/1/60
11.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
168/158
TDX100R948V
65000
60000
100000
93000
93.0
45 - 75
DIRECT
11 x 10
1
4
SEE FAN PERF. TABLE
1/2
1075
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
2 - 16 X 20 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 45
5 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
5
115/1/60
12.5
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
185/175
TDX120R960V
78000
72000
120000
111000
92.5
45 - 75
DIRECT
11 x 10
1
4
SEE FAN PERF. TABLE
3/4
1075
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
2 - 16 X 20 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 45
6 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
6
115/1/60
12.9
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
206/196

Related product manuals