Upflow/Horizontal Right
or Upflow/Horizontal Left
Induced Draft Gas Furnace
XR 80
TUD040,060,080,100,120,140C
Single-Stage Fan Assisted
Combustion System
PUB. NO. 22-1640-06-0702 (EN)
FURN-PRC001-EN
Question and Answer IconNeed help?

Do you have a question about the Trane TUD100 and is the answer not in the manual?

Trane TUD100 Specifications

General IconGeneral
ModelTUD100
AFUE80%
Ignition TypeHot Surface Ignition
WarrantyLimited Lifetime on Heat Exchanger, 5-Year Limited on parts
TypeUpflow
Efficiency Rating80%
Blower Motor TypePSC
Fuel TypeNatural Gas or Propane
Vent TypeCategory I
StagesSingle Stage

Summary

General Features

Natural Gas Models

Details certification by AGA and CSA for natural and L.P. gas.

Safe Operation

Describes solid-state devices monitoring flame presence and dual solenoid gas valve.

Quick Heating

Highlights durable, heavy gauge aluminized steel heat exchanger for heat transfer.

Burners

Mentions multi-port In-shot burners for quiet and efficient service, convertible to L.P. gas.

Integrated System Control

Explains total control of furnace limits, blowers, gas valve, and self-diagnostics.

Air Delivery

Covers 4-speed blower motor, switching speeds for heating/cooling, and blower door safety switch.

Styling

Describes heavy gauge steel, wrap-around cabinet, and foil-faced fiberglass insulation.

Features And General Operation

Details adaptive Hot Surface Ignition, elimination of pilot, and front service access.

Features and Benefits

Standard Equipment

Lists essential components like multi-port burners, solid-state control, and aluminized steel heat exchanger.

Optional Equipment

Encompasses items like thermostats, electronic air filters, and coil enclosures.

General Data

Product Specifications

Presents detailed technical specifications for various furnace models in a tabular format.

Performance Data

Furnace Airflow vs. Static Pressure

Provides data on furnace airflow (CFM) against static pressure in inches w.g.

CFM vs. Temperature Rise

Displays cubic feet per minute (CFM) based on temperature rise.

Field Wiring

Field Wiring Diagram For Heating Only

Illustrates wiring connections for heating-only furnace operation.

Field Wiring Diagram For Single Stage Heating;Cooling

Shows wiring for single-stage heating and cooling configurations.

Twinning Field Wiring

Twinning Connection Diagram for 1 Stage Heating Only Thermostat

Wiring diagram for twin furnaces with a heating-only thermostat.

Twinning Connection Diagram for 1 Stage Heat; 1 Stage Cooling Thermostat

Wiring diagram for twin furnaces with a heat/cool thermostat.

TUD-C Outline Drawing

Dimensions

Shows the physical dimensions of the furnace models.

Minimum Clearance to Combustible Materials

Specifies required clearances for safe installation.

Electrical Data

Schematic Diagrams for Gas Furnaces

Presents electrical schematic diagrams for the gas furnaces.

Speed Taps for I.D. Fan Motor

Details speed tap settings for the induced draft fan motor.