DiMENSiONAL DATA
©
CONTROl 50X
ACCESS PAN _
YC×024=060G OUTLINE = FRONT
152 MM
[61
140 MM
FLUE
(FIELD }NSFALLED)
_COMBUSIlON
BLOWER ACCESS
GAS
ACCESS
D
RECOMMENDED SERVICE CLEARANCE
BACK * 6.0"
LEFT SIDE 30.0"
RIGHT SIDE 24.0"
FRONT SIDE 42.0"
18" WITH FRESHAIR ACCESSORY
30" WITH ECONOMIZER
MODEL
YCX024G-L
YCXO24G-M
YCXO30G-L
YCXO30G-M
YCXO36G-L
YCXO36G-M
YCXO36G-H
YCXO42G-M
YCXO48G-H
YCXO6OG-M
A B C D
56 I/2 36 25 3/16 25 I/8
56 I/2 36 29 3/16 25 I/8
64 36 29 3/16 26 9/16
65 1/8 45 33 5/8 27 15/16
25 MM [1"} DIA. K.O
_OR 15 MM [1/2] NPT
GAS CONNECTION
_CONDENSER CO!L
& GUARD
D66 7952
CLEARANCE TO
COMBUSTIBLE MATERIAL
BOTTOM 0.0"
BACK 1.0"
LEFT SIDE 6.0"
RIGHT SIDE 6.0"
FRONT SIDE 12.0"
TOP 36.0"
Page 5