Page #1 background image
Packaged Rooftop Air Conditioners
Precedent™ — Gas/Electric
3 to 10 Tons — 60 Hz
Installation, Operation, and Maintenance
January 2021
RT-SVX21AC-EN
Model Numbers:
YSC036G - YSC060G YHC072F - YHC102F
Model Numbers:
YSC072H - YSC120H YHC120F
Model Numbers:
YHC036E - YHC072E YHC037E - YHC067E
Model Numbers:
YHC048F - YHC060F
SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of
heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training.
Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury.
When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are
attached to the equipment.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Trane YHC120F and is the answer not in the manual?

Trane YHC120F Specifications

General IconGeneral
BrandTrane
ModelYHC120F
CategoryAir Conditioner
LanguageEnglish

Summary

Introduction

Warnings, Cautions, and Notices

Explains different types of safety advisories used in the manual to ensure user safety.

Model Number Descriptions

3 to 10 Tons (T/Y)

Details the meaning of each digit in the model number for 3 to 10 ton units.

3 to 5 Tons (T/Y - 17 Plus)

Explains the model number coding for 3 to 5 ton, 17 Plus units.

General Information

Unit Inspection

Provides steps for inspecting the unit upon arrival for shipping damage and verifying nameplate data.

Pre-Installation

Fiberglass Wool!

Provides critical safety warnings and PPE requirements for handling fiberglass wool insulation.

Installation

Foundation

Covers critical safety warnings for handling heavy units and provides guidance on installing foundations and footings.

Combustible Materials!

Warns about maintaining clearances between the unit and combustible materials to prevent fire hazards.

Rigging

Includes critical safety warnings and steps for safely rigging and lifting the unit using proper equipment.

Main Electrical Power Requirements

Covers crucial safety warnings regarding hazardous voltage and capacitors, and proper field wiring and grounding.

Field Installed Power Wiring

Provides detailed instructions and guidelines for field-installed power wiring, including conductor sizing and grounding.

Field-Installed Control Wiring

Covers critical safety warnings for hazardous voltage and proper field wiring installation for control circuits.

Pre-Start

Voltage Imbalance

Explains the importance of maintaining proper three-phase voltage balance and how to calculate and address imbalance.

Electrical Phasing (Three Phase Motors)

Details how to verify and correct electrical phasing for proper three-phase motor rotation.

ReliaTel™™ Controls

Outlines the self-diagnostic checks performed by the RTRM upon power initialization.

Fan Test and Minimum Ventilation

Explains how to test the fan operation and minimum ventilation settings using test modes.

Economizer Cooling

Details how to test the economizer cooling function by jumping specific terminals.

Unit Start-Up

Sequence of Operation

Explains the operational sequences for ReliaTel™™ and electromechanical controls, including cooling and heating stages.

ReliaTel™™ Controls - Constant Volume (CV)

Describes the features and operation of the ReliaTel™™ constant volume control system.

ReliaTel™™ Control Cooling without an Economizer

Details the sequence for cooling operation without an economizer using ReliaTel™™ controls.

Supply Air Pressure Control

Explains how the RTOM controls supply fan speed to maintain duct static pressure in VAV applications.

Supply Air Temperature Controls

Explains how supply air temperature is controlled, including economizer use and setpoint adjustments.

Zone Temperature Control

Covers temperature control strategies, including unoccupied cooling, morning warm-up, and daytime warm-up.

Variable Air Volume Applications (Single Zone VAV)

Explains how single zone VAV units are controlled, including supply fan output and discharge air setpoint adjustment.

ReliaTel™ Control Cooling with an Economizer

Describes how the economizer is utilized to control zone temperature and when mechanical cooling engages.

ReliaTel™™ Control Cooling with an Economizer

Details the ReliaTel™™ control sequence for cooling with an economizer, including damper modulation and compressor engagement.

Electromechanical Control Cooling without an Economizer

Explains the cooling sequence for electromechanical units without an economizer, including compressor engagement.

Electromechanical Control Cooling with an Economizer

Details the cooling sequence for electromechanical units utilizing an economizer.

Variable Air Volume Applications (Traditional VAV)

Covers supply air temperature control strategies for traditional VAV systems.

Supply Air Temperature Control - Occupied Cooling and Heating

Explains how the RTRM maintains selectable supply air temperatures for occupied cooling and heating.

Supply Air Temperature Control with an Economizer

Describes economizer use for supply air temperature control and limitations to prevent coil freeze-up.

Supply Duct Static Pressure Control

Explains how supply duct static pressure is measured and controlled via transducer output.

Economizer Start-Up

Provides critical safety warnings and step-by-step procedures for starting up the economizer.

Compressor Start-Up

Details the procedures for starting compressors, including verifying rotation and operating pressures.

Maintenance

Coil Cleaning

Details procedures for cleaning evaporator and condenser coils, including specific instructions for microchannel coils.

Microchannel (MCHE) Coils

Offers specific warnings and recommendations for cleaning microchannel coils to prevent damage.

Round Tube Plate Fin (RTPF) Coils

Describes the recommended method for cleaning round tube plate fin coils using brushes and sprayers.

Troubleshooting

Hazardous Service Procedures!

Provides critical safety warnings for all troubleshooting activities, focusing on electrical and mechanical hazards.

ReliaTel™™ Control

Guides on checking ReliaTel™™ system status and performing diagnostics before turning power off.

Live Electrical Components!

Emphasizes safety precautions when working with energized electrical components.

System Status Checkout Procedure

Explains how to check system status using LED indicators on the zone sensor module or by checking voltage readings.

Method 1 (System Status)

Details the procedure for resetting system failures from the space using the zone sensor mode switch.

Method 2 (System Status)

Explains how to check system status by measuring voltage readings at the RTRM terminals.

Resetting Cooling and Ignition Lockouts

Explains identical methods for resetting cooling failures and ignition lockouts from the space or at the unit.

Unit Economizer Control (ECA) Troubleshooting

Guides on troubleshooting the economizer actuator status and verifying damper operation.

Troubleshooting procedures for Direct Drive Plenum Fan

Offers troubleshooting steps for direct drive plenum fans, including wiring checks and motor reset procedures.