8. MEM/READ key is the SAMPLE WEIGHT READ KEY. Press this key to recall the memorized
sample weight, if more than one sample weight is memorized continue to press this key until the
correct sample weight is selected.
Operation way: input unit weight storage place by number key then press [MEM/READ] key
to catch unit weight.
9. [M+] MEMORY KEY is used when accumulating the counting data. This data is memorized by
pressing this key and can be accumulated up to 99 times.
Operation wayplace weight then press [M+]WEIGHT line will show how many times
=XX=,UNIT WEIGHT line shows flashed [Add]press <Enter> key to confirm it and back to
counting mode. M+ LED indicator will light up when you activate it.press [TOTAL] key to
call out the total value of accumulation
10. MC key is used to clear out the accumulated counting data.
Operation way press<MC> key when the M+LED lightsWEIGHT line will show how many
times =XX =, UNIT WEIGHT line shows flashed [CLr]press <Enter>light off.
11. SAMPLE key is used when setting the counted number of samples on the platter into the scale
memory.
12. UNIT WEIGHT is used when setting the known unit weight data into the scale during normal
operation. (1/1000kg or 1/1000lb)
13. QTY/SET key is used when wanting to switch between the pieces counting function and quantity
check weighing function.
warning setting of minimum or maximum weight .
Press [QTY/SET] keythe display will show CH=OFF, press [Enter] key to select CH=ON.
press[*] keyUNIT WEIGHT line flashedpress number key to input minimum weight.
press [*] keyTOTAL line flashedpress number key to input maximum weight.
press [QTY/SET] key to exit setting mode and back to weighing mode.
If the weight placed under minimum weight at counting mode, the scale will speak out DU DU
DU. If the weight placed exceed maximum weight, the scale will speak out DI DI DI.
14. NUMERIC (0-9) keys are used for setting numeric data for sample numbers, sample weights or to
set a limit for the HI/LO settings.
15. [*] Key is used to change the division when the scale is in SCALE 3 mode.
16. TOTAL key displays the accumulated total pieces on the scale
17. ESC key is used to exit from the current menu
18. CE key is used for cancelling the numeric setting data or cancels the previous unit weight data.
Final Rev 2015.11.25