EasyManua.ls Logo

treesse Minipool REST - Page 15

treesse Minipool REST
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
treesse
treesse
Pg. 15
? DESCRIPTION OF PARTS
Alarms
Filter clogged alarm - If the filter is obstructed, the cleaning cycle is enabled automatically.
If the problem persists, the system locks all the functions and the display shows the message "FL".
In this case, you must power off and on again, after about 30 seconds, the power switch of the product.
LED controller alarm - In the event of failed communication with the controller, the system disables
the function and the display shows the message "Co" alternating with the temperature.
The other functions remain available.
Water level alarm - Both in ACTIVE and STANDBY mode, if there is no minimum water level
for more than 3 seconds, an alarm is activated and the display shows the message "LL" alternating with
the temperature, the hydromassage pump, the recirculation pump, the heater and
the ozonator are disabled.
The alarm and the system automatically resets when the normal operating condition is restored.
Water level sensors alarm - In the event of a malfunction of water level sensors, an alarm will be
triggered, the display shows the message "Fer", the functions are disabled.
In this case, you must power off and on again, after about 30 seconds, the power switch of the
product. dovrà spegnere e riaccendere, dopo circa 30 secondi, l’interruttore di alimentazione del
prodotto.
CONTROL PANEL

Related product manuals