HT/ST Space Humidity and Temperature Sensor Installation Instructions TG200921 Issue 1/B 30/08/06
1 - 1
Installation Instructions - Sheet 1
HT/ST
Space Humidity and Temperature Sensor
Important: Retain these instructions
1.2 Installation
1.1 Unpacking
2
1
HT/ST Installation
Instructions TG200921
Dimensions
1
86 mm (3.39”)
26 mm (1.02”)
86 mm (3.39”)
Requirements
2
b
a
c
> 50 cm (20”)
e
d
f
g
1.5 m
(5 ft)
Contents
1.1 Unpacking ........................................ 1 - 1
1.2 Installation ........................................ 1 - 1
2.1 Maintenance ..................................... 2 - 1
2-2 Disposal ........................................... 2 - 3
Sheet 1
Sheet 2
HT/ST Installation Instructions - Sheet 1
HT/ST Space Humidity and Temperature Sensor Installation Instructions TG200921 Issue 1/B 30/08/06
1 - 4
I Q
1.2 Installation (continued)
Set up IQ Sensor types
12
tYpe Sensor digI/P Driver Function loGic Loop scHedule seQnc Analog
digBit Knob sWitch Time Zone Oss User addRess intcoN calarM reView Plot
calEndar
= ?
Temperature (0 to +40 °C)
Thermistor
Yn<CR>
TYPE n
:
=?
S=5 (characterise)
Y=, E=, U=, L=, P=,
I1 to I6=, O1 to O6=
X <CR>
It is recommended to use SET (software tool) for the setting of sensor type modules. For all IQ2
series controllers with firmware version 2.1 or greater, or IQ3 series controllers, the following SET
Unique Sensor References should be used:
Humidity: Humidity I
Temperature: Thermistor HTST DT (°C)
Thermistor HTST DT F (°F)
(change the values of U and L to +50 and -5 °C or +122 and +23 °F
respectively)
If not using SET, use the following tables for all IQ2 series controllers of firmware version 2.1 or greater
or IQ3 controllers; for all other IQ controllers see Sensor Scaling Reference Card TB100521A.
Humidity (0 to 100 %RH)
Current
Yx<CR>
TYPE x
:
=?
S=5 (characterise )
Y=, E=, U=, L=, P=
I1 to I2=, O1 to O2=
X <CR>
I Q
Δ T
Test system
13
Temperature
Humidity
Δ H
Y epyttupnI)Amrruc(2
E tnenopxE3
U reppU001
L rewoL0
P stnioP2
xxIxO
1 40
2 02001
stinU
C°F°
Y
epyttupnI
)stlovrotsimreht(1
E
tnenopxE
3
U
reppU
05221
L
rewoL
5-32
P
stnioP
6
xxI)C°(xO)F°(xO
1
146.205221
2
74.304401
3
64.40368
4
366.60105
5
866.7023
6
201.85-32
Assemble unit
10
backplate
‘click’
Configure IQ
11
IQ Configuration
Manual 90-1533
IQ
IQ
or
Maintenance
14
HT/ST Installation Instructions - sheet 2
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TREND HT series and is the answer not in the manual?

TREND HT series Specifications

General IconGeneral
BrandTREND
ModelHT series
CategoryStud Sensor
LanguageEnglish