4. Specifications
Chapter 4
Forward Frequency Tuning Range 50 - 1003 MHz
Reverse Frequency Tuning Range 4 - 110 MHz
Amplitude Measurement Range
Analog: 40 dBmV to +50 dBmV
Digital: -40 dBmV to +50 dBmV
Return < -40 dBmV (Ground Block Test)
IF Bandwidth 6 MHZ standard, 8 MHz optional
Deep Interleave Compatibility Yes
Carrier-to-Noise As per FCC Part 76.605. Carrier and Noise both
measured in same analog channel => 50 dB
Downstream MER 34 dB for => -6 dBmV RF level,
typical: 40 dB for => +6 dBmV RF level
Downstream BER True BER (derived from code words not from MER)
Range: 1 E-7 to 1 E-9 for signal => -6 dBmV
ITU J.83 annex A, B, C
Communications DOCSIS 3.0 Modem (8x4)
Bluetooth (optional USB plug in)
USB A
Ethernet (10/100)
Wi-Fi 802.11 b/g (optional)
Display Color LCD touch screen;
480 x 272 pixels (approx 4 x 2.25)
Annunciators Audible annunciator for key strokes
Flashlight High intensity LED (0.25W)
Battery Twin 2600 mAh @ 7.2V LiOn packs
Charge Time 3 hours
Operating Time 8 hours continuous
Mechanical Unit housed in rubber overmolded plastic enclosure
Operational Unit controlled via 12 rubber keys and LCD touch
screen and/or via a wireless connection to a mobile
device such as a laptop, tablet, iPad® or iPhone®, or
Android® handset