Trimble M3 Total Station User Guide 39
Before Going to the Field 3
30.1 Frequently used settings (HOT MENU settings)
Press the Trimble key to access the HOT MENU.
B
Tip – When you hold down the Trimble key for one
second in any observation screen, a shortcut screen
appears that enables you to enter the point, code, target
height, and prism constant.
Distance measurement settings (EDM)
1. Press
[1] in the HOT MENU screen to open the
EDM Settings screen.
2. Press
[<] or [>] to change the Mode setting. The
options are
PREC/STD where:
PREC is precise measurement mode
STD is fast measurement mode
3. Press
[v] to move to the AVE field. AVE is the
number of measurements to average when
computing the measured distance value. Enter a
number between 1 and 99.
4. To return to the
HOT MENU screen, press [ESC].
Format (output format) M5, see M5 data format, page 130
Nikon, see Nikon data format, page 142
Parity None
Even
Odd
Baud rate 1200
2400
4800
9600
19200
38400
Position P (only for M5
format)
1 - 16
Position C (only for M5
format)
1 - 23
Position I (only for M5
format)
1 - 21
Options