Do you have a question about the Trimble M3 Total Station and is the answer not in the manual?
| Operating Temperature | -20°C to +50°C |
|---|---|
| Laser Pointer | Yes |
| Internal Memory | 10, 000 points |
| Battery Type | Li-ion |
| Measurement Time | 1.2 seconds |
| IP Rating | IP66 |
| Distance Accuracy (Prism) | ±(2mm + 2ppm) |
| Distance Accuracy (Reflectorless) | ±(3mm + 2ppm) |
| Distance Range (Prism) | Up to 3000 m |
| Distance Range (Reflectorless) | 500 m |
| Weight | 5.1 kg |
| Communication | USB |
Thanks the user for purchasing the instrument and advises reading the manual.
Describes the ease of use and features of the Trimble M3 total station.
Illustrates the system components of the Trimble M3 total station.
Provides contact information for dealers and training courses.
Guides users on how to get technical support for the instrument.
Requests feedback from users to improve documentation.
Details the main physical parts of the Trimble M3 total station.
Provides instructions for maintaining the instrument to ensure its longevity.
Describes the instrument's display and the functions of its keys.
Summarizes the functions of the various keys on the Trimble M3 series.
Explains how to adjust display and audio settings for optimal usability.
Describes the indicators displayed on the status bar of the instrument.
Provides instructions for safely unpacking and packing the instrument.
Details the procedures and safety precautions for battery charging and discharging.
Guides users on how to select the instrument's operating language.
Explains how to configure regional settings for the instrument.
Covers essential settings for instrument operation, including angle, distance, and system configuration.
Provides instructions for properly setting up the tripod for instrument stability.
Explains how to accurately center the instrument over the station point.
Details the procedure for leveling the instrument to ensure accurate measurements.
Guides users on how to focus the telescope for clear target viewing.
Covers selecting measurement modes and preparing targets for accurate readings.
Explains the procedures for powering the instrument on and off.
Explains the different measurement modes available on the instrument.
Guides users on how to navigate and change the instrument's display screens.
Details how to switch between different distance measurement units.
Provides instructions for taking measurements using the instrument.
Explains how to use the continuous measurement (tracking) mode.
Guides users on setting and resetting the horizontal angle.
Details how to input target and instrument heights for accurate measurements.
Explains how to set the station elevation for improved measurement accuracy.
Covers the use of the Intersection program for measuring geometric features.
Provides instructions for creating new survey jobs on the instrument.
Guides users on how to open previously created survey jobs.
Explains the process for deleting survey jobs from the instrument.
Details how to designate a job as a control point file for reference.
Explains how to view details and status of existing survey jobs.
Guides users on how to edit data within survey jobs.
Explains the resection method for determining station setup using known points.
Details how to set up the instrument using a known station point.
Describes the function for determining station elevation using known points.
Guides users on measuring topographic points to capture terrain data.
Explains the stakeout functions for setting out designed points in the field.
Explains how to measure distances between points indirectly.
Details how to determine heights of inaccessible objects.
Covers determining coordinates relative to a reference line.
Explains how to define and measure points within a vertical plane.
Guides users on calculating areas using measured points.
Details the physical connectors and pinouts for data communication.
Lists technical specifications related to data transfer and communication.
Explains the XON/XOFF protocol for data transmission.
Guides users on transferring data from the instrument to a PC.
Provides detailed steps for exporting recorded data to a computer.
Explains how to import data from a PC into the instrument.
Covers importing point name/number lists from a computer.
Details importing point code lists from a computer.
Guides users on checking and adjusting the instrument's plate level.
Details the process for checking and adjusting the circular level.
Explains how to check and adjust the optical plummet for accurate centering.
Describes how to verify and potentially adjust the instrument constant for distance measurements.
Covers the critical adjustments for the compensator and index errors.
Guides users on aligning the laser pointer for precise measurements.
Addresses error messages and solutions related to point data and coordinates.
Offers solutions for issues concerning interface settings and data formats.
Provides troubleshooting steps for problems related to job creation and management.
Addresses errors and solutions specific to stakeout operations.
Solves issues related to importing point name and code lists.
Helps resolve errors encountered during instrument calibration and adjustment procedures.
Provides solutions for problems encountered within specific instrument applications.
Details the structure and specifications of the M5 data format.
Explains the Nikon data format for coordinate records and other data types.
Covers the file format for point lists and code lists.
Lists the specifications for the instrument's telescope.
Details the instrument's measurement range under various conditions.
Specifies the precision of distance measurements in different modes.
Lists the time taken for measurements in various modes.
Details the specifications for angle measurement accuracy and display.
Provides specifications for the instrument's dual-axis tilt sensor.
Specifies the type and range of clamps and tangent screws.
Lists the type of tribrach used with the instrument.
Specifies the sensitivity of the instrument's level vials.
Lists the specifications for the optical plummet.
Details the specifications of the instrument's display and keypad.
Describes the communication and power connections available.
Provides specifications for the instrument's battery pack.
Lists the operating and storage temperature ranges.
Provides the physical dimensions of the instrument and accessories.
Lists the weights of the instrument and its components.
Lists and defines the softkeys used within the instrument's software.
Provides definitions for common surveying and instrument-related terms.