5 Basic Measurement Screen
62 Trimble M3 Total Station User Guide
50.1 Instrument height (ih) and station-Z coordinate (Zs)
To input instrument height (ih) and station Z
coordinates (
Zs):
1. Press
[F3] ih/Zs in the STN Elevation screen.
2. Select a method to input Station height.
– To input from recorded data, press
[F1]
Internal memory.
– To input directly using the keypad, press
[F3]
Input.
3. Input the Zs coordinate. Do one of the following:
– Enter the coordinates using the keypad and
then press
[MEAS/ENT].
– To use previous input, press
[F3] Stack,
select the required value and then press
[MEAS/ENT].
4. Input the instrument height. Do one of the
following:
– Enter the instrument height using the
keypad and then press
[MEAS/ENT].
– To use previous input, press
[F3] Stack,
select the required value and then press
[MEAS/ENT].
5. The STN Elevation screen shows the result. Do
one of the following:
– To exit the program without saving the
result, press
[F1] No.
– To record the result on the screen and finish
the program, press
[F4] Yes.