Trimble M3 Total Station User Guide 89
Coordinates 7
70.1 Stakeout by angle and distance (HD or HDh)
1. From the Stake out menu, select [2] HD or
[4] HDh. A confirmation screen appears enabling
you to verify the current station coordinates.
2. Do one of the following:
To terminate the program, press
[F1] No.
To show the Scale edit screen, press
[F2] m.
To accept the station coordinates and
proceed to the reference direction
confirmation screen, press
[F4] Yes.
The
Reference Dir screen enables you to
confirm the reference direction.
3. Do one of the following:
To terminate the program, press
[F1] No.
To accept the backsight point angle and
proceed to the
Input HD & Az screen,
press
[F4] Yes.
Note – When you select
[4] HDh, the station elevation
confirmation screen appears when you confirm the
reference direction in the horizontal angle.
4. In the
Input HD & Az screen, do one of the
following:
Input the coordinate values.
To select from previously input values, press
[F3] Stack.
To accept new or existing values and move
to the observation screen, press
[F4] o.k..
Note – If you press
[F4] without having entered any value
in the field, the current HA reading will automatically be
set as AZ.
5. Sight the point and press
[MEAS/ENT] to take a
measurement to the point.
Note – The th softkey appears only when you have
selected
[4] HDh.