TrimbleR10ReceiverWebHelp
Loggingrate
Positionrate
Elevationmask
Theseparametersarealwaysresettothefactorydefaultvalueswhenthereceiverisswitchedoff.
PowerUpapplicationfile
Thepowerupapplicationfile(Power_up.cfg)isusedtosetthereceivertoaspecificconfiguration
anytimetheunitispoweredup.
Inthisfile,youcanspecifythatthereceiverisresettodefaultsbeforethepowerupsettingsare
applied.Thisensuresthatrestartingthereceiveralwaysresets
ittofactorydefaultsbeforeapplying
thepowerupapplicationfile.
Alternatively,youcanspecifythatthepowerupsettingsareappliedimmediatelyafterthecurrent
applicationfile’ssettingshavebeenapplied.Restartingthereceiverresultsinaconfigurationthat
usesyourdefaultsettingsfortheoptionsyoudefinein
thepowerupfile,butthecurrentsettings
forallotheroptions.
Bydefault,thereisnopower_upapplicationfileonthereceiver.Touseapowerupapplicationfile,
youmustcreateandsaveapower_upapplicationfileintheGPSConfiguratorsoftware.Ifyousave
thisfileto disk,
thefileiscalledpower_up.cfg.Theextension.cfgisused,byconvention,toidentify
applicationfilesontheofficecomputer.Whenyoutransferthisfiletothereceiver,thefileissaved
onthereceiveraspower_up,andbecomesthenewpowerupfile.
Applyingapplicationfiles
Anapplicationfile’s
settingsdonotaffectthereceiver’sconfigurationuntilyouapplythe
applicationfile.Youcandothisatthesametimethatyousavethefile.Alternatively,youcansave
thefileonthecomputeroronthereceiver,thenopenitlaterandapplyitssettings.
Storingapplicationfiles
You
canstoreapplicationfilesthatyoucreateintheGPSConfiguratorsoftwareonthereceiverand
onthecomputer.Forexample,eachfilecanrepresentadifferentusersharingthesamereceiver,
oraparticularmodeofoperation.Savingapplicationfilesonyourcomputeraswellasinyour
receiver
isoptional,butitisusefulbecause:
itgivesyouapermanentcopyofthesettingsyouhavesenttoareceiver,forauditpurposesor
foryourownreference.
youcanusethesamefiletoconfiguremultiplereceiversidentically.
youcanuseanexistingapplicationfile
asatemplatetocreateotherapplicationfileswith
similarsettings.
Namingapplicationfiles
Theapplicationfilenameintheofficecomputerandinthereceiverarealwaysthesame.This
makesiteasiertorecognizeandkeeptrackofyourapplicationfiles.
Whenyouchangethenameoftheapplication
fileinthereceiver,thischangestheapplication
filenameonyourcomputer.Whenyoutransferanapplicationfilefromthereceiverandsaveitto

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trimble R10 and is the answer not in the manual?

Trimble R10 Specifications

General IconGeneral
Channels440
RTK Horizontal Accuracy8 mm + 1 ppm RMS
RTK Vertical Accuracy15 mm + 1 ppm RMS
Operating Temperature-40 °C to +65 °C
L1 C/A CodeYes
L2EYes
L2CYes
L5Yes
BeaconNo
FM RadioNo
WAASYes
MSASYes
EGNOSYes
Storage Temperature-40 °C to +75 °C
Ingress ProtectionIP67
Positioning Accuracy (Static) - Horizontal3 mm + 0.5 ppm RMS
Positioning Accuracy (Static) - Vertical5 mm + 0.5 ppm RMS
Signal TrackingBeiDou
RTK Initialization< 8 seconds
Battery LifeUp to 7 hours
SBAS Accuracy50 cm
Glonass CodeL1 C/A, L2 C/A
CommunicationsBluetooth