10
DC Milliamperes
Ranges: 0-.6, 6, 60, 600
Accuracy:
±
3% of full scale value
Approximate Full Scale
Current Range Voltage Drop
0-.6, 6, 60 mA 250 mV
0-600 mA 330 mV
Meter
50
μ
A - 250 mV (Pivot and Jewel)
Overload Protection
Meter movement protected by diodes.
RX1 range protected by fuse.
Voltage ranges protected by high impedance.
Batteries
One 1.5 volt N-cell (NEDA 910) (PN: 37-21)
One 12 volt Eveready A23 (PN: 37-60)
Fuse
1/16A (PN: 3207-112)
Weight
Approximately 14 oz.
Accessories Supplied with Model 310 / 310-C
1. Test leads w/Screw-on Alligator clips (PN: 79-153)
2. Batteries: One 1.5V (PN: 37-21)
One 12V (PN: 37-60)
3. Instruction Manual (PN: 84-894)