Configuration Altimeter Product Manual
0286-SOM-00001, Issue: 09 39 © Tritech International Ltd.
SW1 Dip Switches Input/Output
ID 1 2 3 4 5 6
String
Output
Format
Output
Behaviour
Output if
no echo
received
Interrogate
Character
4 0 0 1 0 0 0 000.000m Interrogated Zero Z
5 1 0 1 0 0 0 000.000m Free Running Zero n/a
6 0 1 1 0 0 0 000.000m Interrogated Maximum Z
7 1 1 1 0 0 0 000.000m Free Running Maximum n/a
8 0 0 0 1 0 0 00.000m Interrogated Zero Z
9 1 0 0 1 0 0 00.000m Free Running Zero n/a
10 0 1 0 1 0 0 00.000m Interrogated Maximum Z
11 1 1 0 1 0 0 00.000m Free Running Maximum n/a
12 0 0 1 1 0 0 000.00m Interrogated Zero Z
13 1 0 1 1 0 0 000.00m Free Running Zero n/a
14 0 1 1 1 0 0 000.00m Interrogated Maximum Z
15 1 1 1 1 0 0 000.00m Free Running Maximum n/a
16 0 0 0 0 1 0 Bathymetric Interrogated Zero Z
17 1 0 0 0 1 0 NMEA Free Running Zero n/a
18 0 1 0 0 1 0 NMEA Free Running Maximum n/a
32 0 0 0 0 0 1 A000.000m Interrogated Zero A
33 1 0 0 0 0 1 B000.000m Interrogated Zero B
34 0 1 0 0 0 1 C000.000m Interrogated Zero C
35 1 1 0 0 0 1 D000.000m Interrogated Zero D
36 0 0 1 0 0 1 E000.000m Interrogated Zero E
37 1 0 1 0 0 1 F000.000m Interrogated Zero F
38 0 1 1 0 0 1 G000.000m Interrogated Zero G
39 1 1 1 0 0 1 H000.000m Interrogated Zero H
40 0 0 0 1 0 1 A000.000m Interrogated Maximum A
41 1 0 0 1 0 1 B000.000m Interrogated Maximum B
42 0 1 0 1 0 1 C000.000m Interrogated Maximum C
43 1 1 0 1 0 1 D000.000m Interrogated Maximum D
44 0 0 1 1 0 1 E000.000m Interrogated Maximum E
45 1 0 1 1 0 1 F000.000m Interrogated Maximum F
46 0 1 1 1 0 1 G000.000m Interrogated Maximum G
47 1 1 1 1 0 1 H000.000m Interrogated Maximum H
Note
On SW1 settings with ID0 to ID3 are for factory use only. ID19 to ID31
and greater than ID47 relate to application specific configurations. If the
altimeter has a switch setting that is not listed, please contact Tritech prior
to making any changes.