5
HYDROLINK™ WATERING SYSTEM WITH SNAKE™ TUBING
5
5 BEFORE INSTALLING YOUR HYDROLINK WATERING
SYSTEM KIT (Kit purchased separate from your Trojan batteries)
DANGER! - POISON / ACID
The battery contains acid, and may release explosive gases. Wear eye protection at all times. No smoking,
sparks or open flames near batteries. In the event of an acid spill, avoid contact with skin, eyes and clothing.
SHIELD EYES.
EXPLOSIVE GASES
CAN CAUSE
BLINDNESS
OR INJURY
FLUSH EYES
IMMEDIATELY
WITH WATER.
GET MEDICAL
HELP FAST.
SULFURIC ACID
CAN CAUSE
BLINDNESS OR
SEVERE BURNS
NO
•SPARKS
•FLAMES
•SMOKING
1. Remove the vent caps and inspect the fill wells.
2. Check electrolyte level:
a) If electrolyte level is below the plates:
Manually add enough water to cover the plates. (Refer to Trojan Battery’s User Guide, Table 4 for
Water Impurity Limits, available at www.trojanbattery.com.)
Charge batteries to 100% full charge, before using the HydroLink Watering System.
WARNING! DO NOT OVERFILL THE CELL. ADDING TOO MUCH WATER TO THE
CELL WILL CAUSE THE BATTERY TO OVERFLOW ACID DURING THE CHARGING
PROCESS CAUSING CORROSION AND POTENTIAL INJURY.
b) If electrolyte level is inside of the fill well, the cell is overfilled. Do not install the system at this time.
Wait for the electrolyte levels to go down normally (under battery usage). After levels are normal, fully
charge the batteries and continue to Section 6, Installation.