Info and Notes on Instructions

Follow the Manual

Information marked with this symbol indicates that the instructions must be observed.

Symbols Explanation

Explanation of warning symbols used in the manual for safety and hazard identification.

Safety Guidelines

General Safety Warnings

Read all safety warnings and instructions to prevent electric shock, fire, and serious injury.

General Safety Precautions

Avoid explosive rooms, aggressive atmospheres, ensure stable position, and avoid wet conditions.

Electrical Safety

Ensure cables are protected, use proper mains connection, and avoid damaged cables.

Refrigerant Safety Warnings

Position only in rooms where leaking refrigerant cannot accumulate to avoid fire/explosion hazards.

Safety Information (Continued)

Intended Use

Use for drying and dehumidifying room air, including living rooms, bedrooms, and garages.

Foreseeable Misuse

Do not place on wet ground, cover, use outdoors, or immerse in water; no unauthorized modifications.

Personnel Qualifications

Users must be aware of dangers in damp areas and have read the instructions.

Residual Risks and Warnings

Residual Risks

Covers dangers from flammable refrigerants (R290/R454C) and electrical hazards.

Electrical Shock Risk

Device not suitable for wet rooms; risk of electric shock; never immerse in water.

Toy Warning

The device is not a toy and does not belong in the hands of children.

Device Information and Emergency Behaviour

Device Description

Uses condensation principle to dehumidify rooms by cooling air below dew point.

Device Depiction

Visual representation of the dehumidifier with numbered components.

Behaviour in the Event of an Emergency

Steps for emergencies: switch off, disconnect from mains, do not reconnect defective device.

Transport and Storage

Transport Precautions

Switch off, disconnect mains, drain condensate, do not drag by cable, wheel on firm surfaces.

Transport Handle and Wheels

Device is fitted with a transport handle and wheels for easier transport.

Assembly and Start-up

Scope of Delivery

Lists items included: device, air filter, condensation drain hose, manual.

Unpacking the Device

Open box, remove device, remove packaging, fully unwind power cable carefully.

Storage Instructions

Drain condensate, disconnect mains, store in dry, protected, upright, dust-free location.

Start-up Procedures

Positioning the Device

Observe minimum distances from walls/objects as per Technical annex.

Inserting the Air Filter

Ensure filter is inserted before switching on to prevent contamination and damage.

Inserting the Condensation Tank

Ensure float is correctly inserted and tank is empty and correctly seated.

Operation Guide

Operating Element Overview

Description of controls like rotary switch, mains switch, and LEDs for tank full and status.

Connecting the Power Cable

Insert the mains plug into a properly secured mains socket.

Operation Details

Status LED Interpretation

Interprets Status LED flashes for normal operation, faults, or specific error conditions.

Switching On and Starting Up

Device functional after 3-5 mins; ensure drain hose connected, use large container.

Continuous Operation Mode

Device dehumidifies constantly regardless of humidity; set rotary switch to Max.

Operation Features

Automatic Defrost

Evaporator may freeze below 11°C; device performs automatic defrost; do not switch off.

Temperature Limitation (Overheating Protection)

Device protects compressor from overheating; switches off compressor if limits are exceeded.

Shutdown and Error Handling

Electrical Safety During Shutdown

Do not touch mains plug with wet hands; switch off, hold plug when disconnecting.

Available Accessories

Lists specified accessories and warns against using unauthorized items.

Errors and Faults

Troubleshooting guide for issues like device not starting or no condensate formation.

Fault Diagnosis and Error Codes

Compressor and Performance Issues

Troubleshooting for compressor not starting, or device performance loss due to dirt.

Error Codes

Interprets Status LED flashes for normal operation, faults, or specific error conditions.

Maintenance Schedule

Maintenance and Care Intervals

Table detailing maintenance tasks and their frequency: before start-up, as needed, 2/4/6 months, annually.

Maintenance and Care Log

Logbook section for recording maintenance activities with date and signature.

Maintenance Preparations

Electrical Safety Before Maintenance

Switch off device, hold plug when disconnecting, do not touch plug with wet hands.

Opening Device Warning

Tasks requiring device opening must only be done by authorized specialists or Trotec.

Cleaning the Housing

Use soft, damp, lint-free cloth; protect electrical components; avoid aggressive cleaners.

Visual Inspection of the Inside

Remove air filter, use torch to inspect inside, clean by specialist if dusty.

Cleaning and Tank Management

Cleaning the Air Filter

Ensure filter is not worn; clean filter when dirty using damp cloth or warm water.

Emptying the Condensation Tank

Condensation tank indicator illuminates when full or incorrectly installed; compressor/fan switch off.

Post-Maintenance Activities

Resuming Operation

Reconnect the device to the mains to continue using it after maintenance.

Technical Specifications

Technical Data

Detailed specifications for TTK 175 S and TTK 355 S, including performance and dimensions.

Electrical Diagrams

Wiring Diagram with Operating Hours Counter

Shows electrical connections for the device with an optional time counter.

Advanced Wiring Configurations

Wiring Diagram with Time and Energy Counters

Shows electrical connections with optional time and energy counters (MID approved).

Assembly and Spare Parts

Exploded Assembly Drawing

Visual breakdown of the device components for assembly and repair.

Spare Parts Position Numbers

Notes that position numbers for spare parts may differ from component descriptions.

Spare Parts Catalog

List of Spare Parts

Comprehensive list of spare parts with their corresponding numbers for identification.

Disposal Guidelines

WEEE Directive Compliance

Device must not be disposed of with household waste; find collection points for proper recycling.

Refrigerant Disposal

Dispose of refrigerant (propane) appropriately by certified companies according to national regulations.

Declaration of Conformity

Product Identification and Compliance

Declares compliance with EC Machinery Directive for TTK 175 S and TTK 355 S dehumidifiers.

Manufacturer Information

Provides manufacturer details and contact information for Trotec GmbH.

EU Directives and Standards

Lists relevant EU directives and harmonised standards applied to the product.

Overview

The Trotec TTK 175 S and TTK 355 S are professional-grade dehumidifiers designed for drying and dehumidifying room air, suitable for various environments such as living rooms, bedrooms, basements, holiday homes, camper vans, storage spaces, archives, laboratories, garages, and changing rooms. These devices operate on the principle of condensation to automatically remove moisture from the air.

Function Description:

The dehumidifier works by drawing damp room air through an air inlet, an air filter, and then over an evaporator and condenser. The air is cooled at the evaporator to below its dew point, causing water vapor to condense or freeze on the evaporator fins. The dehumidified, cooled air is then slightly warmed by the condenser and blown back into the room. This continuous circulation reduces the humidity in the room. The condensed water collects in an integrated drain nozzle, flowing into a condensation tank equipped with a float to measure the filling level. For continuous operation or unattended dehumidification, a hose can be attached to the condensation connection to drain water directly. The device can reduce relative humidity to approximately 30%. An operating element allows for control and function management.

The compressor always starts with a delay of approximately 3 minutes, which protects it and extends its lifespan. This delay also applies after the condensation tank is emptied and reinserted, or during optional hygrostat operation when the room humidity exceeds the set point. The fan operates independently of the compressor and only switches off if the condensation tank is removed.

The device features an automatic defrost function. If the room temperature falls below 11 °C, the evaporator may freeze during dehumidification, and the device will automatically initiate a defrost cycle. During this process, the device continues to operate, and the mains plug should not be removed.

A temperature limitation (overheating protection) is integrated to protect the compressor. If the ambient temperature exceeds +35 °C (+/- 2 °C) or falls below -3 °C (+/- 2 °C), the compressor automatically switches off, while the fan continues to run. This prevents overloading and ensures economical operation, as drying at extreme temperatures is less efficient and can pose risks to room inventory. The switch-off function includes a switch-on hysteresis of -2 °C.

Important Technical Specifications:

Parameter TTK 175 S (1.120.000.157) TTK 175 S (1.120.000.159) TTK 355 S (1.120.000.163)
Dehumidification performance @ 30 °C / 80% RH 40 l / 24 h 40 l / 24 h 55 l / 24 h
Dehumidification performance, max. 50 l / 24 h 50 l / 24 h 70 l / 24 h
Operating range (temperature) 5 °C – 32 °C 5 °C – 32 °C 5 °C – 32 °C
Operating range (relative humidity) 50 % – 90 % RH 50 % – 90 % RH 50 % – 90 % RH
Max. permissible pressure 3.0 MPa 3.0 MPa 3.0 MPa
Pressure suction side 0.6 MPa 0.6 MPa 0.6 MPa
Pressure outlet side 2.1 MPa 2.1 MPa 2.2 MPa
Air volume flow 580 m³/h 580 m³/h 1,000 m³/h
Mains connection 220-240 V / 50 Hz 110 / 230 V ~ 50 Hz 220-240 V / 50 Hz
Power consumption, max. 0.6 kW 0.6 kW 1.3 kW
Nominal current 2.8 A 5.7 / 2.7 A 6 A
Fusing - 10 A -
Type of protection IPX0 IPX0 IPX0
Water tank capacity 6 l 6 l 6 l
Refrigerant R290 (propane) R290 (propane) R454C (F-Gas)
Amount of refrigerant 150 g 150 g 650 g
GWP factor 3 3 146
CO2 equivalent 0.00045 t 0.00045 t 0.09490 t
Sound pressure level LpA (1 m) 52 dB(A) 52 dB(A) 54 dB(A)
Dimensions (L x W x H) 390 x 380 x 643 mm 390 x 380 x 643 mm 390 x 380 x 725 mm
Minimum distance to walls/objects (top, rear, sides, front) 50 cm each 50 cm each 50 cm each
Weight 35 kg 39 kg 39 kg

Usage Features:

  • Portability: Equipped with a transport handle and wheels for easy movement. The transport handle can be adjusted after unpacking by removing two lower screws.
  • Operating Element: Features an operating hours counter, an optional kilowatt-hours counter (MID-certified), a rotary switch for selecting relative room humidity, a mains switch (illuminated when on), a condensation tank LED (indicates full or incorrectly installed tank), and a status LED (indicates operating status and error messages).
  • Air Filter: An air filter is essential for operation to prevent internal contamination and maintain performance. It must be inserted correctly before switching on.
  • Condensation Tank: The tank must be correctly inserted and empty before operation. If removed or incorrectly installed, the device will not switch off.
  • Condensate Drainage: Water can be collected in the internal tank or drained continuously via a hose connected to the condensation connection.
  • Optional Condensate Pump: The device can be operated with an optional condensate pump via the TTKwic port and Qube, ensuring continuous operation.
  • Continuous Operation Mode: By setting the rotary switch to "Max," the device dehumidifies continuously regardless of humidity.
  • Safety Features: Includes warnings for flammable refrigerants (R290 propane or R454C), electrical voltage, and general hazards. Minimum room sizes (13 m² for R290, 4 m² for R454C) and distances from ignition sources must be observed.

Maintenance Features:

  • Regular Checks: Before each start-up, check air inlets/outlets for dirt, clean the exterior, and visually inspect the device's interior.
  • Air Filter Maintenance: The air filter should be cleaned or replaced if dirty, which can be indicated by reduced performance. It must be dry before reinsertion.
  • Condensation Tank Maintenance: Regularly empty the condensation tank and check the float for dirt.
  • Refrigerant Circuit: The entire refrigerant circuit is a maintenance-free, hermetically sealed system. Maintenance or repair must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.
  • Running Capacitor: Replace after 10,000 operating hours.
  • Housing Cleaning: Clean the housing with a soft, damp, lint-free cloth. Avoid moisture entering the housing and do not use aggressive cleaning agents.
  • Internal Inspection: Periodically inspect the device's interior for dirt. If a thick layer of dust is present, have it cleaned by a specialist company.
  • Error Codes: The Status LED (17) provides visual indications of operating status and error messages, such as normal operation, temperature limits exceeded, or humidity level reached.
  • Storage: Before storing, drain all condensate, disconnect from mains, and store in an upright position in a dry, frost- and heat-protected location, away from direct sunlight and ignition sources.
  • Disposal: Packaging materials and the device itself must be disposed of in an environmentally friendly manner, adhering to local and national regulations. Devices containing fluorinated greenhouse gases or flammable refrigerants require specialized disposal by certified companies.