16
Check
Resolution
The plate meter is not turned on
Turn on
The battery is flat
Replace the battery
If you have just changed a battery you
may have damaged the battery snap
clip to top of the battery.
Service: Send the plate meter to your
service agent
Check
Resolution
This is normally due to a low battery.
The plate meter requires a given level of
power to operate correctly. If the
battery doesn’t have sufficient power it
may continuously beep to warn you.
Remember if you turn the plate meter
off for a few minutes it may recover
slightly but the problem will not go
away.
Change the battery
Battery may be due for replacement.
Requires electronic service.
Most problems are due to the plate meter being out of calibration (see
following points as to why. If in doubt it is worth Zero Calibrating just to
make sure it is correct (see page 6).