EasyManua.ls Logo

True TAC-30 - Page 22

True TAC-30
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
............ www.truemfg.com ............
True Food Service Equipment, Inc.
20
20
HOW TO INITIATE A MANUAL DEFROST
May need to unlock control.
WHY:
A ONE TIME ADDITIONAL DEFROST MAY BE NECESSARY
TO CLEAR ACCUMULATED FROST/ICE FROM EVAPORATOR
COIL.
HOW:
emethodtoinitiateamanualdefrostisdeterminedby
theDefrostModeParameter“DTM”preprogrammedin
thecontroller.
A. REGULAR TIME DEFROST (TIM)
Ifcontrollerispreprogrammedfor“TIM”,pressand
releasetheManualDefrostbuttonuntil“dEF”appears.
B. REAL TIME CLOCK (RTC)
Ifcontrollerispreprogrammedfor“RTC”pressthe
andholdtheManualDefrostbuttonfor5seconds
until“dh1”appears.ReleasetheManualDefrostbut-
tonandthenpressandholdforanadditional5seconds
until“dEF”appears.
LAE Electronic Control
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/
Up Button
Stand-By
Button
Compressor
Running
Activation of 2nd
Parameter Set - NA
Alarm - NA
Cabinet in Defrost
Evaporator Fan
Running
LAE Control Icons