US Operating instructions Page 2
Installation instructions Page 25
To be kept in the vehicle.
This document is part of the water heater.
Truma AquaGo® LP Gas Instant Water Heater
Model: Truma AquaGo® basic (DLE60B) *
Truma AquaGo® comfort (DLE60C) * * Patent Pending
Truma AquaGo® comfort plus (DLE60CP) *
Sales and Service
Truma Corp.
825 East Jackson Blvd.
Elkhart, IN 46516
USA
Toll Free 1-855-558-7862
Fax 1-574-538-2426
info@trumacorp.com
www.truma.net
Conforms to ANSI Std. Z21.10.3
Certified to CSA Std. 4.3
4010007
If the information in these instructions is not
followed exactly, a fire or explosion may result,
causing property damage, personal injury, or
death.
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Evacuate all persons from the vehicle.
Shut off the gas supply at the gas container
or source.
Do not touch any electrical switch, or use
any phone or radio in the vehicle.
Do not start the vehicle’s engine or electric
generator.
Contact the nearest gas supplier or certified
service technician for repairs.
If you cannot reach a gas supplier or certi-
fied service technician, contact the nearest
fire department.
Do not turn on the gas supply until gas leaks
have been repaired.
Installation and service must be performed by
a certified service technician, service agency,
or the gas supplier.

Table of Contents

Other manuals for Truma AquaGo comfort plus

Questions and Answers

  • N
    Nicole PhillipsAug 15, 2025
    Why is there no hot water at the tap in my Truma AquaGo comfort plus?
    • C
      Christine WilliamsAug 15, 2025
      If you're not getting hot water from your Truma Water Heater, several factors could be the cause: * The gas supply might be off or interrupted. Ensure the gas supply is turned on. * The gas tank could be empty. Refill or replace the gas tank. * The appliance might be switched off. Turn on the appliance according to the operating procedures. * The fresh water supply could be turned off. Open the fresh water supply. * The power supply to the appliance might be off. Turn on the power supply. * There may be a defect in the appliance. If LED 2 is blinking red, contact a certified service technician.
  • B
    Brian PopeAug 18, 2025
    What to do if water is escaping from the pressure relief valve of my Truma AquaGo comfort plus Water Heater?
    • C
      Cheryl ColeAug 18, 2025
      If water is escaping from the pressure relief valve, it could be due to a few reasons: * The water pressure in the system might be too high. Adjust the water pump pressure to a maximum of 450 kPa. If connected to a central water supply exceeding 450 kPa, install a water pressure reducer like the Truma water pressure regulator at the fresh water supply. * Water might not be able to expand in the system. Contact your vehicle manufacturer about retrofitting a pressure compensation element. * There could be lime or dirt under the valve seat. After the appliance cools, slowly raise the test lever to flush the system and try to remove any debris. If this doesn't work, have a certified service technician replace the pressure relief valve.
  • A
    alivingstonAug 21, 2025
    Why is the hot water temperature too low in my Truma AquaGo comfort plus Water Heater?
    • A
      Audrey MartinezAug 21, 2025
      A low hot water temperature can be caused by: * Low gas flow to the appliance (gas inlet pressure < 2,62 kPa). Check your vehicle documentation to ensure the gas supply provides enough gas. A service technician can verify the gas installation. * High hot water volume flow or low cold water temperature. Reduce the hot water flow at the tap or shower. A certified technician can install a volume flow throttle. * Too much lime scale in the appliance. Decalcify the appliance.
  • C
    Caitlin LongAug 25, 2025
    What to do if there is no hot water at the Truma Water Heater faucet?
    • J
      James NguyenAug 25, 2025
      If you're not getting any hot water from your Truma Water Heater, here's what to check: * Ensure the gas supply is turned on and hasn't been interrupted. * Make sure your LP gas tank isn't empty – refill or replace it if needed. * Verify that the Truma AquaGo™ instant water heater is switched on. * Confirm that the fresh water supply is open. * Check that the power supply to the Truma AquaGo™ instant water heater is on. * If LED 2 is blinking red, it indicates a defect; in this case contact a certified service technician.
  • A
    Anna AdkinsAug 27, 2025
    Why is water escaping at the pressure relief valve of my Truma AquaGo comfort plus Water Heater?
    • D
      diazlaurenAug 28, 2025
      If water is escaping from the pressure relief valve, it could be due to a few reasons: * The water pressure in the system might be too high. Try adjusting the water pump pressure or consider replacing it. Installation of a pressure limiter should be performed only by a certified service technician. * The water may not be able to expand properly within the system. Contact your vehicle manufacturer about retrofitting a pressure compensation element. * There might be lime or dirt under the pressure relief valve seat. To resolve this, slowly raise the test lever to flush the system and attempt to dislodge any debris. If this doesn't work, the pressure relief valve may need replacement by a certified service technician.
  • N
    nielsenalexisAug 30, 2025
    What to do if the yellow LED 3 is off on my Truma Water Heater?
    • X
      xcarrollAug 30, 2025
      If the yellow LED 3 is off even when an operating mode is selected, check the following: * Ensure the power switch is ON. Switch on the appliance at the POWER switch. * Verify the appliance has power. Switch on the power supply to the appliance. * If the power supply was interrupted, reset the system by switching OFF at the control panel, waiting 2 seconds, and then switching it on again.
  • F
    Frances ShortSep 2, 2025
    How to stop boiling noises from my Truma Water Heater?
    • W
      wclineSep 2, 2025
      Boiling noises indicate too much lime scale in the appliance. You must decalcify the appliance.
  • R
    Rhonda SantosSep 5, 2025
    What to do if water is escaping at the water inlet filter of my Truma AquaGo comfort plus?
    • D
      Desiree HerreraSep 5, 2025
      If water is escaping at the water inlet filter, it's likely due to lime or dirt under the O-ring seats. Clean the O-rings and their corresponding sealing surfaces with clean water.
  • T
    Travis MillerSep 8, 2025
    Why is the hot water temperature too low on my Truma AquaGo Water Heater?
    • C
      cherylpaulSep 8, 2025
      If the hot water temperature from your Truma AquaGo™ is too low (less than 120°F / 49°C), consider these potential causes: * The gas flow to the heater might be insufficient (gas inlet pressure less than 10.5" wc). Consult your vehicle documentation to check if the gas supply provides enough gas volume. * The hot water volume flow could be too high, or the incoming cold water temperature might be too low. Reduce the hot water flow at the faucet or shower. A certified service technician can retrofit a volume flow throttle into the water system. * Excessive lime deposits might be present in the heater. Have it decalcified by a certified service technician.
  • E
    erikastoneSep 12, 2025
    What to do if water is escaping at the water inlet filter of Truma Water Heater?
    • J
      Jamie AlvarezSep 12, 2025
      If you notice water escaping at the water inlet filter, it's likely due to lime or dirt under the O-ring seats. Clean the O-rings and their corresponding sealing surfaces using clean water.

Summary

Truma AquaGo LP Gas Instant Water Heater

Important Safety Warnings

Key safety alerts including fire, explosion, and gas leak procedures.

Appliance Overview and Parts Identification

Consumer Safety Information

Safe Operation Guidelines

Malfunction Handling and Repair

Procedures for handling malfunctions and requirements for maintenance.

Appliance Safety Features

Operating the Water Heater

Access Door Procedures

Starting the Appliance and Initial Checks

Steps for starting the appliance and essential pre-use inspections.

Switching the Appliance On

Winter Operation

Winterizing Procedures

Appliance Maintenance

Decalcification Process

Decalcification Methods

Safety Precautions for Decalcification

Warnings and safety measures related to decalcification agents.

Decalcification Step-by-Step Guide

Troubleshooting Common Problems

Installation Instructions

Safety Practices for Installation

Essential safety measures to follow during appliance installation.

Selecting the Installation Location

Preparing the Installation Site

Preparing the Gas Connection

Gas Rear Connection

Preparing the Water Connection

Preparing the 12 V DC Electrical Connection

Mounting the Control Panel

Connection Diagrams

Installing the Appliance

Gas Connection Finalization

Connecting Gas Line (Rear)

Checking for Gas Leaks

Functional Check

APPENDIX A - Error Codes

APPENDIX B - Functional Diagram

APPENDIX C - Spare Parts List

APPENDIX D - Electrical Connection Diagram

Truma AquaGo comfort plus Specifications