12
Battery protect voltage setting
Press the “<>” button one more time after
change °F or °C, to enter battery protect
voltage setting. Then press the “+/-” but-
tons to choose HI, ME or LO of protect
level.
Battery
protect
level:
On
(12 V)
Off
(12 V)
On
(24 V)
Off
(24 V)
LO
(low)
11.1 ±
0.3 V
10.1 ±
0.3 V
23.3 ±
0.3 V
21.5 ±
0.3 V
ME
(medium)
12.2 ±
0.3 V
11.4 ±
0.3 V
25.3 ±
0.3 V
24.1 ±
0.3 V
HI
(high)
12.6 ±
0.3 V
11.8 ±
0.3 V
26.2 ±
0.3 V
24.6 ±
0.3 V
Bluetooth setting
Press the “<>” button one more time after
battery protect voltage setting, to enter
Bluetooth activity. Then press “+/-” but-
tons to choose ON or OFF.
Press the “<>” button and “+” button for
three seconds, at the same time to enter
the Bluetooth mode.
CLO
CLOSE*
Connect to the refrigerator by
scan the QR code only.
OPE
OPEN*
Scan and find your refrigerator
by mobile Bluetooth, and then
connect.
*on Dual Zone models
Multi voltage system /
Emergency Override
Risk of fire. Only the
100V-240 V AC inlet or one of the two
12/24V DC inlets may be used. Use of both
connections at the same time is not permitted.
Risk of fire.Only one of the
two 12/24 V DC inlets may be used on the de-
vice. The connection that is not used must be
closed using the supplied blanking plug.