EasyManua.ls Logo

Truma C30 - Page 8

Truma C30
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Damage may occur if the DC cable supply
is not appropriately sized. This will cause
low voltage. The table below provides rec-
ommended cable sizing from battery to
appliance:
Cable cross
section in
mm² (AWG)
12 V
maximum
cable length
in m (ft)
24 V
maximum
cable length
in m (ft)
2.5 (13) 2.5 (8.2) 5 (16.4)
4 (11) 4 (13.1) 8 (26.2)
6 (10) 6 (19.6) 12 (39.3)
10 (7) 10 (32.8) 20 (65.6)
When using the appliance ensure the cir-
cuit being used has a fuse or circuit break-
er. The recommended size for DC12V is
10A, DC24V is 5A.
Make sure that the voltage data on the
type plate matches the existing power sup-
ply. Incorrect mains supply can damage the
appliance. This is especially important for
ACgenerators that can generate voltage
spikes.
If your appliance is plugged in to a DC ve-
hicle socket, ensure that you disconnect
from power when the vehicle is not in use
to prevent battery drainage.
Never disconnect the appliance by pulling
the cable instead of the plug.