Unusual noise when refrigerator is working
The refrigerator is not placed on a level surface
If none of the above solves your issue please contact the Truma Service Center (855-558-7862).
Fault indicator
Please note that the fault indicator will always be green if normal. When flashing, it will
change to orange color.
Errorcode
(App)
Number of flash-
es
(every 4 seconds)
Fault Descripton / Solution
ER 0 - Broken temperature
sensor
When the LED display will show E0,
means NTC (the temperature sen-
sor) broken circuit or short circuit.
Please contact the Truma Service
Center for support.
ER 1 1
Low voltage
Try on different power source (ve-
hicle or 240VAC power). If chang-
ing power source fixed issue, then
possible issue with original power
source.
Ensure cabling between appliance
and battery is at least 1.5mm²
(AWG15), if the distance is more
than 2 meters use at least 2.5mm
(AWG13) cable.
ER 2 2
Fan issue
Fan is drawing too many amps (over
0.6 amps).
ER 3 3
Compressor start issue
Unplug cable and allow appliance to
rest for 10 minutes.
Try on different power source (ve-
hicle or 240VAC power).
Electronic box fault.
ER 4 4
Low motor speed
Reduce products/items inside
appliance.
Move so appliance is in a lower am-
bient temperature, clean vents/en-
sure clear air flow over compressor.
ER 5 5
Over temperature
Move so appliance is in a lower am-
bient temperature.
Clean vents/ensure clear air flow
over compressor.
If these measures do not remedy the malfunction, contact your dealership, Truma Service or one of
our authorized Service Partners.