Truma CP - Page 10

Truma CP
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Fault Cause Remedy
(only on Combi D 6 E) – No 230 V operating voltage
– 230 V fuse defective
– Longer period of non-use, e.g.
over the winter months
– Restore 230 V operating voltage
– Replace 230 V fuse
– Operate the heater in diesel mode for approx. 30 minutes – then
switch over to electric mode
– Overheating protection has
been triggered
– Reset the overheating protection, allow the heater to cool, remove
the connection cover and press the reset button
Yellow LED flashes 3 x – Open window above cowl
(window switch)
– Close windows
Yellow LED flashes 4 x – Warm air temperature and / or
water temperature exceeded:
– Not all warm air ducts are
connected
– Warm air outlets blocked
– Circulated air intake blocked
– Check whether the 4 warm air ducts are connected
– Check the individual outlet openings
– Remove the circulated air intake blockage
– Summer mode with empty
water container
– Fill boiler with water
Yellow LED flashes 5 x – Room temperature sensor or
cable defective
– Contact Truma Service
Yellow LED flashes 6 x – Water temperature exceeded in
summer mode
– Fill boiler with water
Yellow LED flashes 7 x – Control panel or control panel
cable defective
– Contact Truma Service
Yellow LED flashes 8 x – FrostControl heating element
has a short circuit
– Disconnect heating element plug from electronic control unit,
replace heating element
If these actions do not remedy the problem, please contact Truma Service.