Troubleshooting guide
Fault Cause Remedy
Drain valve (FrostControl) is
opening.
Temperature at drain valve
below approx. 3 °C. (the drain valve
opens automatically at temperatures
below approx. 3 °C!)
Switch on vehicle heater if necessary.
At temperatures above approx.7 °C at the
drain valve, it can be closed again.
The drain valve (FrostControl) can
no longer be closed.
Temperature at drain valve is
below approx. 7 °C.
Rotary switch not set to
Operation”.
Switch on vehicle heater if necessary.
At temperatures above approx.7 °C at the
drain valve, it can be closed again.
Turn the drain valve’s rotary switch to
Operation”, then press the pushbutton until
it engages.
Water flows intermittently from
the FrostControl discharge nozzle.
Water pressure too high. Check pump pressure (max. 2.8 bar). If the
boiler is connected to a central water supply
(rural or urban connection), a pressure reducer
must be used, which will prevent pressures
higher than 2.8 bar from occurring.
If these actions do not remedy the problem, please contact Truma Service.