EasyManuals Logo

Truma FrostControl User Manual

Truma FrostControl
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
Troubleshooting guide
Fault Cause Remedy
Drain valve (FrostControl) is
opening.
Temperature at drain valve
below approx. 3 °C. (the drain valve
opens automatically at temperatures
below approx. 3 °C!)
Switch on vehicle heater if necessary.
At temperatures above approx.7 °C at the
drain valve, it can be closed again.
The drain valve (FrostControl) can
no longer be closed.
Temperature at drain valve is
below approx. 7 °C.
Rotary switch not set to
Operation”.
Switch on vehicle heater if necessary.
At temperatures above approx.7 °C at the
drain valve, it can be closed again.
Turn the drain valve’s rotary switch to
Operation”, then press the pushbutton until
it engages.
Water flows intermittently from
the FrostControl discharge nozzle.
Water pressure too high. Check pump pressure (max. 2.8 bar). If the
boiler is connected to a central water supply
(rural or urban connection), a pressure reducer
must be used, which will prevent pressures
higher than 2.8 bar from occurring.
If these actions do not remedy the problem, please contact Truma Service.

Table of Contents

Other manuals for Truma FrostControl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma FrostControl and is the answer not in the manual?

Truma FrostControl Specifications

General IconGeneral
MaterialPlastic
Protection classIP 44
TypeFrostControl
ActivationAutomatic opening at low temperatures
Operating voltage12 V
WeightApprox. 110 g

Related product manuals