U s e A n d M a i n t e n a n c e I n s t r u c t i o n s
E conomizer E8T 16 Output Channel s
I n Mn E E8 T
e n R ev . 0 0
T UR B O S rl
D u s t F i l t e r C o m p o n en t s
V i a P o 3 3 / 3 5 2 0 8 11 C e s an o M a d e r n o ( M B ) I t a l y T e l + + 3 9 0 3 6 2 5 7 4 02 4 F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
5
Operating modes
manual, automatic, proportional, special manual.
Selectable pressure unit of measure
kPa, millibar, mmH2O, Inch w.c.
Manual solenoid valve activation.
Operating time expressed in seconds and minutes with selectable values for any
application.
Cleaning function with fan off (post-cleaning) by "dP fan" threshold in automatic
/ proportional mode and by contact in manual / special manual modes, with
selectable number of cycles up to 100.
With the automatic operation, is activated upon reaching the dP Start Cleaning
value, turns off when the low threshold is reached dP End Cleaning.
Hour counter and impulse counter.
Minimum dP alarm "broken sleeve" (with the possibility of inclusion / exclusion).
Maximum dP alarm (clogged filter).
Faulty solenoid valve alarm.
Filter element maintenance alarm (with the possibility of inclusion / exclusion).
Cleaning start from external contact.
Compressed air consent input.
Pre-coating function.