U s e A n d M a i n t e n a n c e I n s t r u c t i o n s
E conomizer E8T 16 Output Channel s
4
T UR B O S rl
D u s t F i l t e r C o m p o n en t s
V i a P o 3 3 / 3 5 2 0 8 11 C e s an o M a d e r n o ( M B ) I t a l y T e l + + 3 9 0 3 6 2 5 7 4 02 4 F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
I n Mn E E 8 T
R e v . 0 0 e n
Technical Specifications
Power Voltage
115 Vac 50-60 Hz ± 10 %
230 Vac 50-60 Hz ± 10 %
Alternative Power Voltage
Upon Request
24 Vac ± 10 %
24 Vdc ± 10 %
Output Voltage For Solenoid 115 Vac 50-60 Hz ± 10 %
230 Vac 50-60 Hz ± 10 %
24 Vac ± 10 %
24 Vdc ± 10 %
Inputs from 4 to 20mA x 1
Outputs Proportionate To Dp Value
For Remote Pressure Reading
from 4 to 20mA x 1
Power Consumption 28 Watts Maximum Load
Alarm Relays 3 Normally Closed
Display
Graphic LCD Backlit Monochromatic
B/W 128 x 64 Pixel
Glass Fuse 5 x 20 mm 115 or 230 Vac 1 x 1 A
24 Vac or 24 Vdc 1 x 3 A
Operating Temperature -10 °C - 55 °C
Storage Temperature -20 °C - 60 °C
Environmental Humidity 0 ÷ 95% Relative
Non Condensing
Valve Opening Impulse Time 50 m.sec. - 10 s
Interval Pause Time Between
Valve Opening
1 sec. – 7200 sec.
Measurable Pressure 0 - 10 kPa
Maximum Pressure Applicable
To The Gauge
50 kPa – 0.5 bar
Higher pressures will
damage the device
Casing ABS Base
Polycarbonate Cover
Protection Degree From Water And Dust
IP65 DIN EN 60529
Shock Resistance IK07 2 Joule (EN62262).