This document is a user manual for the TURBRO Split Air Conditioner, covering models FM9K115, FM9K230, FM12K115, FM12K230, FM18K230, and FM24K230. It provides essential information for first-time use, installation, operation, and maintenance.
Function Description:
The TURBRO Split Air Conditioner is designed to provide cooling and heating for indoor spaces. It utilizes R32 flammable refrigerant, requiring careful handling during installation and maintenance. The unit consists of an indoor unit and an outdoor unit, connected by refrigerant pipes, signal cables, and a power cable. The indoor unit features a front panel, filter, air outlet, air inlet, manual button, and deflector. The outdoor unit includes an air inlet, air outlet, wiring box, and pipe connections. The air conditioner can be operated via a remote control or a dedicated mobile application.
Important Technical Specifications:
The manual provides wiring diagrams and electrical specifications for different models. For 115V models (FM9K115, FM12K115), the minimum circuit ampacity is 14A, minimum wire cross-sectional area is 1.5mm², recommended wire gauge is AWG 16+, and recommended breaker size is 115V 30-Amp. For 230V models (FM9K230, FM12K230, FM18K230, FM24K230), the specifications vary:
- FM9K230: 8A, 1.0mm², AWG 18+, 230V 20-Amp Double Pole
- FM12K230: 8A, 1.0mm², AWG 18+, 230V 20-Amp Double Pole
- FM18K230: 10A, 1.0mm², AWG 18+, 230V 20-Amp Double Pole
- FM24K230: 15A, 1.5mm², AWG 14+, 230V 30-Amp Double Pole
Refrigerant additional and decreasing charges are also specified based on the model:
- 9K115, 9K230: 0.17 oz/ft additional, 0.21 oz/ft decreasing
- 12K115, 12K230: 0.17 oz/ft additional, 0.21 oz/ft decreasing
- 18K230: 0.26 oz/ft additional, 0.43 oz/ft decreasing
- 24K230: 0.26 oz/ft additional, 0.43 oz/ft decreasing
The included refrigerant pipe length is 13.12ft (4 meters). The manual also details torque specifications for refrigerant pipe connections based on pipe size (inch/mm), Newton meter, and Pound-force foot. For example, a 1/4" (6.35mm) pipe requires 15-25 Newton meters (11.1-18.4 Pound-force foot) of torque.
Usage Features:
The air conditioner offers various operating modes and functions accessible via the remote control or the AIR.ai app.
- Modes: AUTO, COOL, DRY, HEAT, FAN.
- Fan Speed: Adjustable (LOW, MID, HIGH, TURBO, AUTO).
- TIMER Function: Allows delayed start-up or shut-down, programmable in half-hour increments up to 24 hours.
- SWING Function: L/R SWING adjusts horizontal deflector movement, U/D SWING adjusts vertical deflector movement.
- SLEEP Function: Optimizes room temperature for comfortable sleep, automatically increasing temperature in COOL/DRY mode and decreasing in HEAT mode over several hours.
- ECO Function: Available in COOL mode, this function minimizes electricity consumption and automatically exits after 8 hours.
- SILENCE Function: Reduces operational noise (not available in DRY mode).
- I-FEEL Function: Uses a sensor in the remote control to measure ambient temperature and optimize the temperature around the user.
- Anti-F Function: Removes moisture from the evaporator to prevent mold and odors. It runs for 3 minutes after the unit is turned off in COOL/DRY/AUTO (cooling) mode.
- iCLEAN Function: Cleans dust from the evaporator to improve cooling and heating efficiency. It runs automatically within an hour of activation.
- DISPLAY Function: Toggles the LED display on/off on the indoor unit panel.
- LIGHT Function: Automatically activates or deactivates the indoor unit display based on ambient brightness.
- Temperature Unit: Switchable between Fahrenheit and Celsius by long-pressing COOL and HEAT buttons.
- Child Lock: Activates/deactivates by long-pressing HEAT and MODE buttons, preventing accidental changes.
The AIR.ai app allows remote control and monitoring of the unit. It supports Android 6.0 - 13.0 and iOS 11.0 - 17.0, and offers voice control via Alexa or Google Assistant. The app connects via 2.4 GHz Wi-Fi networks.
Maintenance Features:
The manual outlines cleaning and maintenance procedures to ensure optimal performance and longevity of the unit.
- General Cleaning: The outer case should be wiped with a soft dry or wet cloth and neutral detergent. Volatile liquids should be avoided.
- Filter Cleaning: The air filter should be cleaned regularly (every 3-6 months, more frequently in dusty environments). It involves removing the filter, washing it with soapy water (below 113°F/45°C) and mild detergent, air drying it in the shade, and reinstalling. Do not use a hair dryer or other heating elements to dry the filter.
- Filter Clean Reminder: The indoor unit display will flash 5 times after turning off the unit to remind users to clean the filter.
- Maintenance Checklists:
- Pre-Season: Check for obstacles at air inlet/outlet, clean filter, install remote control batteries, check drain pipe for obstructions.
- Post-Season: Clean filter, remove remote control batteries.
- Troubleshooting: A comprehensive troubleshooting guide is provided for common issues, along with malfunction codes displayed on the indoor unit for self-diagnosis. If issues persist, users are advised to contact TURBRO customer support.
- Refrigerant Leakage Detection: Methods include soapy water detection (checking for bubbles) and using a professional leak detector.
- Remote Control Battery Replacement: Requires two AAA 1.5V batteries. Old and new batteries, or different types of batteries, should not be mixed. Batteries should be removed if the remote is not used for a long time.