Inductive angle sensor
with analog output
Ri360P1-DSU35TC-ELi-Exi
Edition • 2016-06-25T06:44:38+02:00
1 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com
Type code Ri360P1-DSU35TC-ELi-Exi
Ident no. 1593015
Measuring principle inductive
Resolution 12 bit
Measuring range 0…360°
Nominal distance 1 mm
Repeatability
ð 0.025 % of full scale
Linearity deviation
ð 0.3 % f.s.
Temperature drift
ð ± 0.02 % / K
Ambient temperature -25…+70 °C
in the explosion hazardous area see instruction
leaflet
Operating voltage 14… 30VDC
at the connection point of the sensor
Residual ripple
ð 10 % U
ss
Rated insulation voltage
ð 0.5 kV
Short-circuit protection yes
Wire breakage / Reverse polarity protection yes/ complete
Output function 2-wire, Analog output
Current output 4…20mA
22 mA loop current during teach
Load resistance current output
ð [(U
B
-14 V) / 20 mA] kò
Sample rate 500 Hz
Valve control Exi (max. 30 V)
Approval acc. to KEMA 03 ATEX 1122 X Issue no. 2
Internal capacitance (C
i
) / inductance (L
i
) 0 nF / 0 µH
Device designation
É II 2 G Ex ia IIC T6 Gb / II 2 D Ex ia IIIC T85 °C
Db
(max. U
i
= 30 V, I
i
= 120 mA, P
i
= 600 mW)
Dimensions 71 x 60 x 35.4 mm
Housing material Plastic, PP-GF30
Housing material, positioning element plastic, PA66 + PA6I/6T-GF40
Connection terminal chamber
Vibration resistance 55 Hz (1 mm)
Shock resistance (EN 60068-2-27) 30 g
Protection class IP67
MTTF 138 years acc. to SN 29500 (Ed. 99) 40 °C
Included in delivery Positioning element P1-Ri-DSU35, countersunk
screw M6 x 25, 2 cylinder screw M5 x 12, 2 lock
washers A5
ATEX category II 2 G, Ex Zone 1
ATEX category II 2 D, Ex Zone 21
Rectangular, housing DSU35
Plastic, PP-GF30-VO
Detection of angular range 0° to 360°
P1-Ri-QR14 positioning element includ-
ed in delivery
Measuring range programmable via
switch in the Terminal chamber
Immune to electromagnetic interference
Resolution, 12-bit
2-wire, 14…30 VDC
Analog output
4 … 20 mA
Terminal chamber
Wiring Diagram
Functional principle
Inductive measuring principle provides
more safety
Based on the functional principle of RLC cou-
pling, the sensor operates absolutely wear-
free and is immune to magnetized metal splin-
ters and other interference fields.
Owing to the differential analysis, the output
signal remains almost unchanged, even if the
position of the positioning element deviates
from the ideal axis of rotation.

Other manuals for turck Ri360P1-DSU35TC-ELi-Exi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the turck Ri360P1-DSU35TC-ELi-Exi and is the answer not in the manual?

turck Ri360P1-DSU35TC-ELi-Exi Specifications

General IconGeneral
Brandturck
ModelRi360P1-DSU35TC-ELi-Exi
CategoryAccessories
LanguageEnglish

Related product manuals