TP9KF
July 2015-A
2. OVERHEAD OBSTRUCTIONS: The area where the lift located should be free of overhead obstructions
such as heaters, building supports, electrical lines etc (Fig. 4).
Fig. 4
3. DEFECTIVE CONCRETE: Visually inspect the site where the lifts will be installed and check for cracked or
defective concrete. (Details on Page 4)
4. FLOOR REQUIREMENTS: The lift should be installed on a 3000 PSI concrete with minimum of 4” thickness.
The Floor should be level with-in gradients of 1/4” within area of the two columns = 135” x 18”).
(See Details for Foundation Anchoring Requirements & Anchoring Tips on Page 4)