12
Flexible Gas Line
or Hard Plumbing
AC/DC Adapter
(OPTIONAL)
(Usage is optional)
* Do not locate either the gas or electrical supply line directly above the flue outlet of the
heater. The heater must be installed in a location so that it is readily accessible for servicing
and have no restriction of airflow for combustion air and exhaust flue.
Shut-off Valve must
be easily accessible.
NOTE: Use only the mounting brackets
provided by the manufacturer.
*All areas around the heater must be
cleared of any combustible materials.
Not to be installed
in between the
mounting brackets.
48”
NOTE: Use only the mounting brackets provided by the manufacturer. Heater must
be leveled only on a Horizontal Axis but can be angled to a maximum of 30 degrees
in reference to the floor. DO NOT mount the heater on a vertical axis. Such
installation is considered unsafe and improper and will automatically VOID the
product’s warranty.