EasyManua.ls Logo

twintex TP-2303E - Line Voltage Conversion; Cleaning

twintex TP-2303E
16 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 14 -
Fuse rating:
Model 220VAC rated input 110VAC rated input
TP-2303E TSD3.15A TSD6.3A
TP-2303K TSD3.15A TSD6.3A
TP-2303 TSD3.15A TSD6.3A
TP-2303TK TSD3.15A TSD6.3A
TP-2305E TSD6.3A TSD10A
TP-2305K TSD6.3A TSD10A
TP-2305 TSD6.3A TSD10A
TP-2305TK TSD6.3A TSD10A
TP-30102 TSD10A TSD10A
TP-60052 TSD10A TSD10A
6-2. Line Voltage Conversion
The primary winding of the power transformer is tapped to permit operation from 110 or 220Vac ±10%,
50/60Hz line voltage. Conversion from one line voltage to another is done by change AC input selector switch.
The rear panel identifies the line voltage to which the unit was factory set. To convert to a different line voltage,
perform the following procedure:
1) Make sure the power cord is unplugged.
2) Change the AC select switch to the desired line voltage position.
3) A change in line voltage may also require a corresponding change of fuse value. Install the correct
fuse as listed on rear panel.
lf the output voltage is unstableness, please check the AC line that it may be less than 207V/105V.
6-3. Cleaning
To clean the power supply, use a soft cloth dampened in a solution of mild detergent and water. Do not spray
cleaner directly onto the instrument, since it may leak into the cabinet and cause damage.
Do not use chemicals containing benzene, benzene, toluene, xylene, acetone, or similar solvents.
Do not use abrasive cleaners on any portion of the power supply.
Should the problems can not be solved, please contact local distributor or the manufacturer.