5
Setting humidity (Combi heaters)
Use the function selection buttons (F) to select humidity setting. Use the - and + buttons to then select
humidity setting 0-10. 0 (O󰀨) is selected by pressing < while humidity is set to 1. The LED scale indica-
tes the time steam tank is On and O󰀨. During the heating up period of the sauna, the amount of steam
produced depends on the set temperature. When the temperature setting is 1-5 steam will be produced
according to the set humidity (see table below, steam priority). When the temperature setting is 6-10
steam production will not start untill the temperature has reached its target (temperature priority).
Door Switch
Door switch is not used in North America.
Using an external switch
An external switch for starting/stopping the heater not mounted on the control panel can be connected.
A door contact must be installed. See wiring diagram supplied with external switch for connection. We
recommend using Tylö’s external switch (item number 90908045). This also provides indication via LED
of whether the sauna is on, programmed for delayed start and error status for a magnetic door contact
(if tted)
A continuous light indicates that the heater is on.
Slow ash indicates that the heater is programmed for delayed start.
Rapid ash indicates that the door has been opened when the heater is programmed for delayed start.
Alternatively, the door has been open for more than 5 minutes during operation or has been opened
after the heater has been switched o󰀨. The control panel will then require resetting.
Set temperature (approx. value, °C)
Max temperatur 1 2 3 4 5 6 7 8 9 10
90 °C 60 63 67 70 73 77 80 83 87 90
194 °F 140 145 153 158 163 171 176 181 189 194
Set humidity
Steam priority Temperature priority
1 2 3 4 5 6 7 8 9 10
Steam on (min:sek) 01:45 02:00 02:17 02:33 02:47 03:05 03:20 03:35 03:50 always on
Steam o󰀨 (min:sek) 02:23 02:08 01:51 01:35 01:21 01:03 00:48 00:33 00:18 never o󰀨

Questions and Answers: