Common malfunction analysis
If your ice maker shows E1,E2,E3,E4 code, but you can’t solve it, please take a video
to us, we can help, please contact: support@itylza.com, phone number is
+1(213)352-5535
E1
Ice full
indicator is
on,and
proximity
switch didn't
react
Evaporator connector didn't
assemble well
Re-install the connector
Proximity switch is not
sensitive
Replace the switch
The connector didn't return to
original position
Take away the ice to make the connector
return to original position
E2
Normal to
make ice
Stop every 4 cycles,and the
process of ice drop continued
for 5 min
Proximity switch is not sensitive,replace it
No water in the
tank
The water tank is not plugged
Put the plug back
Use barreled water as water
source
The blue tap didn't rotate to vertical
Use barreled water as water
source,but no water flow
down
The water pipe was jammed, disconnect and
clean it.
Use tap water as water source
Check the water supply
Water slopped
over the tank
Use barreled water as water
source
Check whether the water pipe was inserted
well or not
Use tap water as water source
The blue tap didn't rotate to horizontal
Use tap water as water source
Water pressure is too high,water float can't
work.Adjust the water pressure or replace by
a new one.
Water in the
tank
No water or low flow
Pump is badly clogged up,replace or clean it
The spray pipe is clogged up,clean it
Water flow and
water get cool
Thin ice on the evaporator
Increase the making time through "+"
very solid ice on the evaporator
Reduce the making time through "-"
Some water sprayed to ice
storage tank
Adjust the spray pipe
The water leak from the back
of water tank
The tank need to be adjusted.
Water flow
down but water
is not cool
The main board didn't supply
electricity to compressor
Replace by a new main board
Compressor didn't work
Check the starter,replace by a new one if
needed
Compressor is very hot
Replace
Compressor work but the
connected copper pipe didn't
get cool
The compressor leak
E3
The fan is not
work
The condenser prob is not
sensitive
Unplug the prob or replace by a new one
The fan is jammed
Adjust the fan
Fan is broken
Replace by a new fan
E4
Ice full
The connector didn't return to
original position
Take away the ice to make the connector
return to original position