400Maximum pressure Kgf/
(psi)
160System pressure Kgf/
(psi)
35Normal flow /min
9 cc/min
A and B port leak
Oil temperature:50(122)
Under a load of 100Kgf/
THF 500Recommended fluid
-20~80Operating temperature range
45Maximum flow /min
3. REMOTE HYDRAULIC CONTROL VALVE
3.1 SPECIFICATIONS
9-45
3.1 HYDRAULIC CIRCUIT
Fig. 9-69 Remote hydraulic pump
P:From pump
T:To tank
A:High pressure port
B: Return port