ELECTRIC LIFT TABLE
H-10646, H-10647
TECHNICAL INFORMATION
SAFETY
WARNING! Do not operate this lift table unless
you have been trained to use it, authorized
to do so and have checked that it is in good
condition. The operator should read all of the
warning signs and instructions here and on the
lift table before using it.
Never exceed the maximum capacity of the
table. Maximum rated load capacity is for evenly
distributed loads.
Use caution and be aware of pinch and crush
points. Never put hands or feet in scissor lift
mechanism.
Do not allow anyone other than the operator
to stand in front of or behind the table when
in use.
Keep area under table clear of all objects.
Do not lift people.
Stop operating the lift table if the oil temperature
is too high.
Table should be lowered completely when not in
use.
Do not work with electrical components unless you
are a qualified technician.
Do not use table on angled surfaces.
Platform
Width
Raised
Height
Lowered
Height
SPECIFICATIONS H-10646 H-10647
Load Capacity 3,300 lbs. 5,500 lbs.
Voltage 115V 115V
Phase 1 1
Motor Power 1HP 2HP
Table Length 48" 72"
Table Width 36" 48"
Min. Table Height 8" 9.75"
Max. Table Height 39" 47"
Lift Method Electric Electric
Operating Environment Indoors Indoors
Platform Length
Para Español, vea páginas 7-12.
Pour le français, consulter les pages 13-18.

Questions and Answers

  • T
    Tina CrossAug 8, 2025
    What to do if the U-Line H-10646 Lifting Systems platform will not raise?
    • L
      Lindsay OliverAug 8, 2025
      If the U-Line Lifting Systems platform will not raise, even with the pump running, there are a few potential causes. First, the hydraulic fluid reservoir may be empty and need to be filled. Second, the load might be too heavy, causing the relief valve to operate, in which case you should reduce the load. Finally, the lowering valve might be held open; inspect the lower control for any malfunctions and consider cleaning or replacing the lowering solenoid.
  • C
    Catherine RiveraAug 12, 2025
    What to do if the U-Line H-10646 platform will not lower?
    • C
      Christina FloresAug 12, 2025
      If the U-Line Lifting Systems platform will not lower, first check for any obstructions on the platform or scissor lift and remove them or reposition the lift. If there are no obstructions, the lowering valve may not be opening. Try cleaning or replacing the lowering solenoid. Another possibility is an obstruction in the flow limiting valve, which would require flushing the flow limiting valves.
  • A
    amanda10Aug 16, 2025
    Why does my U-Line H-10646 Lifting Systems platform lower too slowly?
    • B
      Barry DayAug 16, 2025
      If your U-Line Lifting Systems platform lowers too slowly, it could be due to the lowering valve not opening completely. Try cleaning or replacing the lowering solenoid. Another possible cause is an obstruction in the flow limiting valve(s). In this case, flush the flow limiting valve(s).
  • J
    Jessica WeeksAug 20, 2025
    Why will my U-Line H-10646 Lifting Systems platform not remain elevated?
    • M
      Monica SantosAug 20, 2025
      If the U-Line Lifting Systems platform won't stay elevated, the lower valve might be held open. Check the lower control for any malfunctions and clean or replace the lowering solenoid. Alternatively, the pump check valve may not be seated properly. Try cleaning, repairing, or replacing the valve and flush the outlet check.
  • B
    brianhubbardAug 25, 2025
    Why is my U-Line H-10646 Lifting Systems pump leaking?
    • J
      Jennifer ButlerAug 26, 2025
      If the pump on your U-Line Lifting Systems is leaking, it could be due to a couple of reasons. First, check if the reservoir is overfilled with oil and drain any excess fluid. Second, inspect the hoses and fittings for any looseness and tighten them as needed.
  • Z
    Zachary JordanAug 28, 2025
    How to fix leaking cylinders in U-Line Lifting Systems?
    • P
      phillipselizabethAug 29, 2025
      If the cylinder(s) in your U-Line Lifting Systems are leaking, it could be because the cylinder seals are worn or damaged; in this case, you should repack the cylinder(s). Another possible cause is loose valves, fittings, or hoses, which you should tighten.
  • S
    Sheila SchmittSep 2, 2025
    Why is my U-Line Lifting Systems platform bouncing?
    • M
      mariegarrettSep 2, 2025
      If your U-Line Lifting Systems platform is bouncing, it's likely due to air in the hydraulic circuit. To resolve this, raise and lower the platform several times to remove the air and then check the fluid level.