53
Blast Chiller Touch Screen Manual
53
Rev08/04/2015
This function will allow loading a new Software and a new Parameter setting.
To do a Software and Parameter update please collect the necessary files from
your Authorized Service Company. These files will come in a zipped folder,
containing the following files
CHILL.emi
indexemi.arg (NOTE: the file index.arg changes according to the
type of Software Update (Software, only parameters, both
Software and Parameters)
Desm_BlastChiller_900_0251_11A.bin
parA.fac
i. Once the files are available on a PC, connect a USB drive to it
ii. Create a folder on the USB drive and name it “CHILL”
iii. Copy the file
CHILL.emi
and
parA.fac
in the “CHILL” folder
iv.
Exit from the folder and copy the files
indexemi.arg
and
Desm_BlastChiller_900_0251_11A.bin
next to the “CHILL” folder
Repeat steps from v. To xix. described in the previous paragraph “Software
Update (only parameters)”.