68
Parameter Description 5 PANS 115V 5 PANS 230V
SELF CONTAINED 230V
TROLLEY
VRS start battery charging threshold [V/10] 11,1
11,1 11,1 11,1
VRE end battery charging threshold [V/10] 11,3
11,3 11,3 11,3
VRT battery voltage at ending charging for max duration [V/10] 9,8
9,8 9,8 9,8
VBR minimum battery voltage for disabling battery [V/10] 8,6
8,6 8,6 8,6
VAD battery voltage threshold to show "no battery" message [V/10] 3,3
3,3 3,3 3,3
VPD battery voltage threshold to detect presence of battery [V/10] 5
5 5 5
TBK delay time before safety turn off of battery circuit [sec] 60
60 60 60
BOF battery voltage offset [V/10] 0
0 0 0
MST max air temperature during thawing [°C/°F] 50 50
50 50
OFH not used 3
3 3 3
PAT air temperature in pre-thawing cycle [°C/°F] 43 43
43 43
PFT evaporator fan speed in pre-thawing cycle [%] 10
10 10 10
PAC air temperature in pre-soft cooking cycle [°C/°F] 43 43
43 43
PFC evaporator fan speed in pre-soft cooking cycle [%] 6
6 6 6
HHL lower differential heating action [°C/°F] 5 5
5 5
HHH upper differential heating action [°C/°F] 5 5
5 5
MRV nominal mains voltage [V] 115
230 230 220
PRF evaporator fan declared power [W] 100
100 100 100
CMR evaporator speed fan index during RH% control [num] 10
10 10 10
CPR not used 10
10 10 10
CIN not used 0
0 0 0
SPS not used 7
7 7 7
TBC not used 5
5 5 5
LPT not used 0
0 0 0
POF not used 0
0 0 0