Do you have a question about the Uberhaus 87795003 and is the answer not in the manual?
General safety guidelines to prevent injury and property damage.
Specifies the required temperature range for operating the air conditioner.
Provides details on electrical service requirements and grounding for the unit.
Lists error codes and explains the function of various indicator lights on the unit.
Details how to operate the unit in COOL, HEAT, DRY, AUTO, and FAN modes.
Explains how to set the automatic start and stop times for the unit.
Instructions for installing the window slider kit for exhaust hose setup.
Step-by-step guide for installing the unit in a double-hung sash window.
Step-by-step guide for installing the unit in a sliding sash window.
Instructions for connecting and installing the exhaust hose for cooling.
Explains how to manage water drainage from the unit, especially in dehumidifying modes.
Instructions for removing, cleaning, and mounting the air filters.
This document describes the Uberhaus Portable Air Conditioner, model MPN2-12ERN1-BH2, a versatile appliance designed for indoor climate control. It offers several operating modes, including cooling, dehumidifying, heating (on some models), and fan-only operation, making it suitable for various environmental conditions. The unit is equipped with casters for easy mobility and features an auto-sliding panel for the air outlet, which opens automatically when the unit turns on and closes when it turns off.
The portable air conditioner functions primarily to regulate room temperature and humidity. In COOL mode, it lowers the room temperature to a user-selected setting, ranging from 17°C (62°F) to 30°C (86°F). The fan speed can be adjusted across four settings: LOW, MED, HIGH, and AUTO, allowing users to customize airflow intensity.
The DRY mode is designed for dehumidification, effectively removing excess moisture from the air. In this mode, fan speed and temperature settings are not adjustable, and it is recommended to keep windows and doors closed for optimal performance. The exhaust duct should not be connected to a window during DRY mode.
For models equipped with heating capabilities, the HEAT mode allows the unit to raise the room temperature within a range of 17°C (62°F) to 30°C (86°F) for heat pump types, or below 30°C (86°F) for electrical heat types. Similar to COOL mode, fan speed can be selected, though for some models, it may not be adjustable under HEAT mode.
The FAN mode circulates air without cooling or heating, offering adjustable fan speeds (LOW, MED, HIGH, AUTO) to provide a breeze. Temperature settings are not applicable in this mode, and the exhaust duct should not be connected to a window.
The AUTO mode provides intelligent climate control. When selected, the air conditioner automatically chooses between cooling, heating (if available), or fan-only operation based on the user-set temperature and the current room temperature. In AUTO mode, the fan speed is automatically controlled by the unit.
A SLEEP function is available in COOL, HEAT, and AUTO modes. When activated, the set temperature gradually increases (for cooling) or decreases (for heating) by 1°C/2°F over 30 minutes, and then by another 1°C/2°F after an additional 30 minutes. This new temperature is maintained for 7 hours (or 6 hours on some models) before reverting to the original setting, after which the Sleep mode ends.
The unit also features a TIMER function for scheduled operation. Users can set an AUTO ON start time or an AUTO OFF stop time program, or combine both. The timer can be set in 0.5-hour increments up to 10 hours, and then in 1-hour increments up to 24 hours. The selected time registers after 5 seconds.
The air conditioner can be controlled via an operation panel on the unit or through a remote controller. The control panel includes buttons for Power, Up/Down temperature/timer adjustment, Swing, Mode selection, Fan speed, Sleep, and Timer. An LED display shows the set temperature or timer settings.
The remote controller offers comprehensive control over all functions, including power, mode selection, temperature/timer adjustment, fan speed, swing, sleep, and a lock function to prevent accidental changes. It also features a clock display and indicators for various operating modes and settings. The remote controller has a transmission distance of up to 26 ft (8 m) and requires two AAA batteries.
For installation, the unit should be placed on a firm, level surface, allowing at least 1 ft (30 cm) of space from walls and furniture for efficient airflow. It is equipped with casters for easy movement on smooth surfaces. The window slider kit is designed to fit most standard vertical and horizontal windows and can be adjusted in length. For windows narrower than 27 inches, the kit may need to be cut, but the pre-drilled hole should never be cut. Foam seals are provided to ensure a secure and insulated installation.
The exhaust hose is crucial for expelling hot air during COOL mode. It connects to a window exhaust adaptor (Adaptor B) or a wall exhaust adaptor (Adaptor A, for specific models). The hose should be kept as short and straight as possible to maintain efficiency, avoiding over-bending. During FAN or DEHUMIDIFY modes, the exhaust hose should be removed.
Water drainage is necessary, especially during dehumidifying operation. The unit has a drain outlet at the back for continuous drainage using a hose (locally purchased) or a bottom drain plug for manual emptying. When the internal bottom tray is full, the unit will beep 8 times and display "P1," indicating that it needs to be drained. The fan motor will continue to operate, but cooling/dehumidification will stop until the water is removed.
The unit incorporates safety features such as automatic restart after a power outage, resuming operation with the last settings. It also has a 3-minute delay before restarting after being turned off, to protect internal components. The auto-sliding panel is designed with safety in mind, but users are cautioned not to place fingers near the air outlet when the unit is turning off.
Regular maintenance is essential for the optimal performance and longevity of the air conditioner.
Air filter cleaning is recommended at least once every two weeks to prevent dust buildup and maintain efficient fan operation. The unit has two filters: an upper filter and a lower filter. To clean, the filters are removed, gently washed in warm water (about 40°C/104°F) with a neutral detergent, rinsed, and dried in a shady place before reinstallation. The grille and air filter are connected and cannot be separated.
The unit enclosure should be cleaned with a lint-free cloth soaked in a neutral detergent, followed by a dry, clean cloth. Harsh chemicals, gasoline, or thinners should not be used, and the unit should not be washed directly with water to avoid electrical hazards.
For long-term storage, several steps are advised:
The manual also provides a troubleshooting guide for common issues, such as the unit not starting, insufficient cooling, noise/vibration, gurgling sounds, or power shutdowns in heating mode. This guide helps users identify possible causes and suggests remedies, such as draining water, resetting temperature, ensuring windows are closed, cleaning filters, or checking duct connections. For persistent errors (E1, E2, E4, E5, E0, P1), professional service is recommended.
| Brand | Uberhaus |
|---|---|
| Model | 87795003 |
| Category | Air Conditioner |
| Language | English |