24
GB
adapter into the connection
valve hole (7).
- Secure the valve adapter in
the connection valve (7):
push the tensioning lever (8)
towards the connection valve
(position
).
- Plug the valve adapter into
the valve on the inatable
item (remove the valve cap
on the inatable item before-
hand if necessary).
Switching on/off:
5. Switch on the device:
On/off switch ( 6) in “I” position.
6. Switch off the device when the desired
ll pressure is reached:
On/off switch ( 6) in “0” position.
7. Disconnect the cigarette lighter plug
(
5).
Disconnecting the connection valve:
8. Connection without valve adapt-
er (10):
Open the connection valve (7)
tensioning lever (8) and remove
it from the valve on the inat-
able item.
Connection with valve adapter
(10):
Remove the valve adapter from
the valve on the inatable item.
Open the connection valve (7)
tensioning lever (8) and remove
valve adapter.
Air can escape from the valve on the
inatable item when the connection
valve is released. Ensure that the
connection valve is removed quickly.
The manometer is not calibrated.
After inating inatable items on
which incorrect pressure may be
dangerous (e.g. tyres), a specialist
unit with a calibrated device should
therefore be visited.
Operation
Operating instructions
The device is not suitable for continuous
operation.
It has been designed to generate air pres-
sure not air volume.
For large-volume items, please do not
operate the device for longer than 5
minutes without interruption, in order
to prevent overheating and damage to
the device. Then allow it to cool for at
least 20 minutes.
We recommend initially lling a large-
volume item with air in order to then
generate the desired pressure with the
device.
Should you require a pressure greater
than 3 bar for a tyre, do not use the
device for longer than 3 minutes with-
out interruption. Then allow it to cool
for at least 20 minutes.
Air pressure test
The device does not need to be
connected to the cigarette lighter in
order to measure the air pressure.
1. Connect the connection valve (7) (see
“Initial operation”).
2. Read off the air pressure on the ma-
nometer display (2).
3. Disconnect the connection valve (see
“Initial operation”).
The manometer is not calibrated.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ULTIMATE SPEED UMK 10 A1 and is the answer not in the manual?

ULTIMATE SPEED UMK 10 A1 Specifications

General IconGeneral
BrandULTIMATE SPEED
ModelUMK 10 A1
CategoryAir Compressor
LanguageEnglish

Related product manuals