-26-
Problem Cause Measures Reference
The specified amount of oil has not
been added.
Add the specified amount of oil. 3.2
The oil has deteriorated. Replace the oil. 6.3
Leakage occurs from the pipe
connected to the pump.
Locate the leakage with a leakage
detector and stop the leakage.
Our specified oil is not being used. Overhaul the pump and replace
with oil specified by us
6.3
The pressure
does not
decrease.
Oil does not circulate, or the oil
hole of the cover is clogged.
Overhaul and clean the oil hole.
Problem with power supply voltage Set the power supply voltage to
within ±10% of the rated voltage.
3.5
The motor malfunctions. Replace the motor.
Foreign matter has entered the
pump.
Eliminate the foreign matter and
overhaul the pump.
The specified amount of oil has not
been added.
Add the specified amount of oil. 3.2
Oil does not circulate, or the oil
hole of the cover is clogged.
Overhaul and clean the oil hole.
Abnormal
sound is
generated.
Components inside the pump have
burnt out.
Overhaul (replace the damaged
components).
Continuous operation at high
evacuation pressure
A pump is suspended or suction
pressure is set to 1kPa or less.
The specified amount of oil has not
been added. (If the oil amount is not
sufficient, the cooling effect of the
pump will be reduced.)
Add the specified amount of oil. 3.2
The temperature of the evacuated
gas is high.
Mount cooling equipment such as a
gas cooler at the inlet side.
Pump surfaces
are extremely
hot (50 or
more higher
than the room
temperature)
Oil does not circulate, or the oil
hole of the cover is clogged.
Overhaul and clean the oil hole.
The pump is been filled in excess of
the specified amount.
Discharge the oil until it reduces to
the specified amount.
3.2 A lot of oil
splashes out
from the
exhaust port.
Continuous operation is performed
at a high evacuation pressure.
Install an oil mist trap at the outlet
side.
4.8
The oil leaks
outside the
pump.
Deterioration of the O-ring and the
oil seal of the case and cover
Check and replace the O-ring and
oil seal.
6.2