Questions and Answers

  • S
    solisoliviaAug 19, 2025
    What to do if the Ulvac LR Water Pump power cannot be applied?
    • R
      Rebecca PhillipsAug 19, 2025
      First, ensure that the power is correctly supplied to the pump. If the power supply is not the issue, check the wiring connections of the connector, and correct them if they are incorrect. Finally, inspect the pump for any leaks. If a leak is found, disassemble and repair the pump.
  • H
    haydenjohnAug 21, 2025
    Why is my Ulvac LR making an unusual sound?
    • W
      William SimsAug 21, 2025
      An unusual sound from the Ulvac Water Pump can be caused by several factors. The panel might be vibrating. The sound may be high due to resonance in the piping when gas is being fed; try using a pipe with a thicker wall to suppress the sound. Check the exhaust piping, or there may be a leakage at the inlet port, so check the piping and repair it, if needed, or there may be a rise in backing pressure.
  • J
    jennifergreenAug 23, 2025
    What to do if Ulvac LR controller can not activates the Pump?
    • J
      jsmithAug 23, 2025
      If the controller cannot activate the Ulvac Water Pump, make sure that LOCAL mode is selected by pressing the REMOTE/LOCAL switch on the controller. Also, ensure that the STOP SWITCH is turned off. Check if EMERGENCY STOP is displayed, and if so, ensure the emergency stop pin of the remote operation connector is shorted. Finally, verify that INTERLOCK is not displayed; if it is, the external interlock pin of the remote operation connector is not shorted.
  • N
    Nathaniel GonzalezAug 26, 2025
    What to do if my Ulvac LR shows no indication on display?
    • A
      Amber ThomasAug 26, 2025
      If there is no indication on the display of your Ulvac Water Pump, verify that the breaker is turned on. If it is on and there's still no display, consider replacing the instrumentation.
  • O
    oguerreroAug 27, 2025
    What to do if I see WATER FLOW LOW ALARM on my Ulvac Water Pump?
    • A
      andersonamandaAug 27, 2025
      If you see a 'WATER FLOW LOW ALARM' on your Ulvac Water Pump, try opening the flow rate-regulating valve. Also, check if there is insufficient difference pressure at the inlet/outlet ports and increase the supply pressure from the host equipment. Make sure there is sufficient gas supply from host equipment.
  • A
    Austin KleinAug 29, 2025
    What to do if I see DRP/MBP PUMP TEMP HIGH ALARM on my Ulvac LR Water Pump?
    • M
      Madison BradleyAug 29, 2025
      If you see a 'DRP/MBP PUMP TEMP HIGH ALARM' on your Ulvac Water Pump, lower the environment temperature. Also, check for insufficient cooling water and open the flow rate-regulating valve. If you have a booster pump unit of HR series, ensure the inlet pressure is operating within the range from the ultimate pressure to 200Pa. Clean and wash the exhaust pipe if there is an increase in backing pressure.
  • A
    Annette WoodSep 1, 2025
    What to do if the pressure does not lower in Ulvac Water Pump?
    • J
      jennifer65Sep 1, 2025
      If the pressure does not lower in your Ulvac Water Pump, check the piping at the upstream of the PUMP for any clogs in the intake port wire netting. Ensure that the pump operating temperature is static, and if not, measure again one hour later. The ultimate pressure in the Specifications is the value directly above the pump.
  • S
    shellybrownSep 3, 2025
    What to do if I see N PURGE 2 GAS LOW ALARM on my Ulvac LR?
    • T
      Timothy PalmerSep 3, 2025
      If you see an 'N PURGE 2 GAS LOW ALARM' on your Ulvac Water Pump, open the flow rate-regulating valve. Increase the supply pressure from the host equipment if there is insufficient difference pressure at the inlet/outlet ports. Ensure there is a sufficient supply of gas.
  • E
    emilyramirezSep 5, 2025
    What does it mean when my Ulvac LR displays SYSTEM ERROR?
    • J
      Jamie WagnerSep 5, 2025
      If your Ulvac Water Pump displays a 'SYSTEM ERROR', turn off the power and turn it on again. This may resolve the issue if the PC program is out of control or the control power output is low.
  • E
    Eric WilliamsonSep 7, 2025
    What to do if the temperature does not increase in Ulvac LR (only HR series)?
    • J
      Jennifer SmithSep 7, 2025
      If the temperature does not increase in your Ulvac Water Pump (HR series only), operate it for one hour. If the temperature still doesn't increase after a temperature error, turn on the bimetal switch, as it may have been turned off. In case of exhaust pipe issues, operate for one hour, and if the temperature remains low, exchange the mantle heater because the temperature fuse has been cut when the temperature does not increase after of the temperature error.

Summary

Before Use

For Safety Use

Safety Denotation

Defines technical terms and hazard levels for warnings.

Warning Label

Explains labels attached to warning locations for safety.

Specification

Design concept

Explains the purpose and application of the LR/HR series pumps.

Performance and Configuration

Describes the pump's capabilities and physical makeup.

System Flow

Details nitrogen gas and cooling water systems for the pump.

Specifications for utilities

Lists the required utilities and their specifications for pump operation.

Dimensional Drawings

Provides detailed dimensions for various pump models.

Description of Controller

Explains the functions of the controller buttons and indicators.

Utility Panel

Identifies and describes the pump's utility connection ports.

Performance Curve

Graphs illustrating pump performance characteristics like speed and current.

Installation

For Safety Use

General safety precautions for pump installation and operation.

Installation and Storage Requirements

Guidelines for unpacking, transit, storage, and environmental conditions.

Piping

Covers requirements for all pump piping connections.

Wiring

Details on electrical wiring for power and remote control.

Communication

Procedures for PC communication setup and connections.

Operation Procedure

Flowchart for operation

Visual representation of the pump's operational sequence.

Prior Operation

Steps to perform before starting pump operation.

Selecting LOCAL (manual);REMOTE

How to choose between local and remote control modes.

Start and Stop

Procedures for starting and stopping the pump.

Checking the Pump Run Status

How to monitor the pump's current operating status.

Set item change

Instructions for modifying operational set items.

Run Mode

Details the different operational modes available for the pump.

List of set items

A list of configurable parameters and their settings.

Self-Diagnostic Function

Explains how the pump monitors itself for abnormalities.

Logging Function

Describes how the pump records operational events and alarms.

Inspection And Maintenance

Inspection

Routine checks to perform on the pump and controller.

Maintenance

Recommended schedules for pump overhauling and part replacement.

TROUBLESHOOTING

Major Troubles

Identifies common pump symptoms and their corrective actions.

In Case of Alarm Signal

Lists alarm signals and their causes/solutions.

WARRANTY TERMS

Warranty Product

Identifies the specific product covered by the warranty.

Warranty Period

Specifies the duration of the product warranty.

Warranty Coverage

Details what is and is not covered by the warranty.

How to Respond

Instructions on contacting ULVAC for service or support.

Others

Additional information regarding contracts and product usage.

Attached material

About the exchange of FUSE (CE Type)

Guidance on replacing fuses in CE type pumps.

Communication system supplementation.

Communication connector connection chart.

Diagrams showing RS-232C and RS-485 connector pin assignments.

Communication command.

Lists commands for controlling and monitoring the pump via PC.