EasyManua.ls Logo

UNI-T UPO3000E Series - Pulse Width Trigger Setup

UNI-T UPO3000E Series
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNI-T
UPO 3000E&UPO2000E Series Oscilloscope Programming Manual
:TIMebase:INDPendent
Command format:
:TIMebase:INDPendent { {1|ON} | {0|OFF} }
:TIMebase:INDPendent?
Functional description:
The switch setting of independent mode of time base.
Return format:
Query return 1 or 0it presents ON or OFF.
For example:
:TIM:INDP ON turn on independent mode of time base
:TIM:INDP? query return 1
FUNCtion Command
Display the operational result plus, minus, multiply, divide, AND, OR, negation,
exclusive OR and FFT of CH1,CH2,CH3,CH4 waveform, set filter to use expression
operation.
:FUNCtion:MATH:MODE
Command format:
FUNCtion:MATH:MODE {MATH|FFT|LOGic|FILTer|ADVance}
FUNCtion:MATH:MODE?
Functional description:
Select MATH function mode.
Return format:
Query return{MATH|FFT|LOGic|FILTer|ADVance}.
For example:
FUNC:MATH:MODE FFT select MATH mode as FFT mode
FUNC:MATH:MODE? query return FFT
:FUNCtion:OPERation
Command format:
:FUNCtion:OPERation {ADD | SUBTract | MULTiply | DIVide | AND|OR|NOT|XOR}
:FUNCtion:OPERation?
Functional description:
Set functional operator, including basic operation and logic operation, they are plus, minus,
multiply, divide, AND, OR, negation, exclusive OR.
Return format:
Query return{ADD | SUBTract | MULTiply | DIVide | AND|OR|NOT|XOR}.