UT502A Insulation Resistance Tester is designed with brand-new
design and combination of massive integrated and digital circuits; it
can measure insulation resistance, low resistance, AC voltage, etc,
and enjoys high degree of accuracy, stable performance, easy
operation and reliability. It is used for insulation resistance
measurement for insulation materials and various kinds of electric
equipments such as transformer, electric machines, cables, switches,
electrical appliances, a ideal tool for electric equipment maintenance,
testing and inspection.
2. Safety Information
The instrument is designed and manufactured in compliance with
IEC61010 standard. The manual covers safety information related to
the safe operations and conditions of the instrument. please read
carefully before using the instrument.
Warning
Use always as specified in the manual, and keep it for future use.
conditions and actions that may cause serious or
fatal damage.
Alerts users to avoid electric shock.
conditions and actions that may cause damage to
the instrument or affect accurate measurement.
voltage over 750VAC.
leads
When test leads are shorted and connected to the instrument, do
not press TEST key.
during test.
Do not touch the tested line during insulation measurement.
Eg: the
instrument was damaged or had exposed metal.
is
discharged.
between test leads
lead
lead
low battery indicator shows If
properly.
3. Electrical Symbols
Risk of electric shock
Accuracy: ±(a% of reading + b digits), calibration per year.
Insulation Resistance Measurement
Polarization Index/Dielectric Absorption Ratio Measurement
Low Resistance Measurementc
Open-circuit voltage
Measurement range
Resolution ratio
Accuracy
Approx. 5.0V
0.00~200
Ω
0.01Ω
± (2%+3)Ω
Criterion Best
Best
Good
Good
Bad
Bad
DAR Value
Criterion
DAR Measurement
DAR Measurement
PI Measurement
PI Value
10min insulation resistance/1min insulation resistance
Greater than
or equal to 4
4---2
2.0---1.0
Less than or
equal to 1.0
Warning
Greater than
or equal to 1.4
1.25--1.0
Less than or
equal to 1.0
1min insulation resistance/30s insulation resistance
1min insulation resistance/15s insulation resistance
500V
1000V
2500V
Rated voltage
Short circuit current
Accuracy range
Measurement
range
Open circuit
voltage
Rated measurement
current
0.00MΩ ~ 5.00GΩ 0.00MΩ ~ 5.00GΩ 0.00MΩ ~ 20.0GΩ
DC 500V+10%
DC 1000V+10%
DC 2500V+10%
Under 500KΩ
1.00mA~1.10mA
Under 1MΩ
1.00mA~1.10mA
Under 2.5MΩ
1.00mA~1.10mA
Approx. Less than 1.8mA
0.00MΩ~99.9MΩ: ±(3%+5)
100MΩ~10GΩ: ±(5%+5)
10.0GΩ~20.0GΩ: ±(10%+5)
Voltage Measurement
AC voltage
Measurement range
Resolution
Accuracy
30~750V (50/60Hz)
1V
±
(2%+3)
Low battery indication:
.
Overload indication: "22.0GΩ" shows under insulation
resistance measurement.
display the unit and function simultaneously
Automatic voltage release
Backlight for work on dark sites
Red light for warning
(Altitude: <2000m)
under normal condition)
operating manual, carrying case.
test leads,
Safety compliances: Overvoltage CATIII 600V, Pollution
Degree 2 as per IEC61010
5. Tester's Structure(Front View)
measurement
for
measurement
7 Switch button for PI/DAR
8 TEST button
9 Rotary knob
LCD Display
6. Buttons and Rotary Knob
1. PI/DAR button: measures polarization index/dielectric absorption
ratio.
2. ZERO/LIGHT button: turns on/off the backlight or resets the
display to zero for low resistance measurement.
3. TEST button: turns on/off insulation and low resistance
measurement.
4. Rotary knob set to ACV: to measure AC voltage.
5. Rotary knob set to CONTINUITY: to measure low resistance.
Question and Answer IconNeed help?

Do you have a question about the UNI-T UT502A and is the answer not in the manual?

Summary

Instrument Overview

Safety Information and Precautions

General Safety Warnings

Provides critical warnings, dangers, and cautions for safe operation and to prevent damage.

Electrical Symbols

Technical Specifications

Insulation Resistance Measurement Specs

Details rated voltage, measurement range, current, and accuracy for insulation testing.

Polarization Index;Dielectric Absorption Ratio

Specifies criteria and values for PI and DAR measurements.

Low Resistance Measurement Specs

Defines open-circuit voltage, range, resolution, and accuracy for low resistance tests.

AC Voltage Measurement Specs

Details measurement range, resolution, and accuracy for AC voltage.

Testers Front View Components

Component Identification

Identifies key jacks, LCD screen, backlight, and buttons on the tester's front panel.

Controls and Operation

Button Functions

Explains the function of PI/DAR, ZERO/LIGHT, and TEST buttons.

Rotary Knob Functions

Details how to use the rotary knob for ACV, CONTINUITY, and insulation test voltages.

Preparations Before Measurement

Low Battery Indication

Describes the low voltage symbol and the need for battery replacement.

AC Voltage Measurement Procedure

Measurement Steps

Guides on setting the rotary knob, connecting leads, and safety precautions.

Low Resistance Measurement Procedure

Measurement Steps

Outlines wiring, discharge, and test procedure for low resistance.

Insulation Resistance Measurement

Voltage Selection and Procedure

Details selecting test voltage, wiring, and performing continuous measurement.

Polarization Index Measurement

Instructions for measuring PI using the PI/DAR button and TEST button.

Dielectric Absorption Ratio Measurement

Steps for measuring DAR using the PI/DAR button and TEST button.

Battery Replacement Procedure

Replacement Steps

Provides instructions and safety warnings for replacing batteries.

Maintenance

Cleaning and Servicing

Guidelines for cleaning the instrument housing and professional servicing.

Summary

Instrument Overview

Safety Information and Precautions

General Safety Warnings

Provides critical warnings, dangers, and cautions for safe operation and to prevent damage.

Electrical Symbols

Technical Specifications

Insulation Resistance Measurement Specs

Details rated voltage, measurement range, current, and accuracy for insulation testing.

Polarization Index;Dielectric Absorption Ratio

Specifies criteria and values for PI and DAR measurements.

Low Resistance Measurement Specs

Defines open-circuit voltage, range, resolution, and accuracy for low resistance tests.

AC Voltage Measurement Specs

Details measurement range, resolution, and accuracy for AC voltage.

Testers Front View Components

Component Identification

Identifies key jacks, LCD screen, backlight, and buttons on the tester's front panel.

Controls and Operation

Button Functions

Explains the function of PI/DAR, ZERO/LIGHT, and TEST buttons.

Rotary Knob Functions

Details how to use the rotary knob for ACV, CONTINUITY, and insulation test voltages.

Preparations Before Measurement

Low Battery Indication

Describes the low voltage symbol and the need for battery replacement.

AC Voltage Measurement Procedure

Measurement Steps

Guides on setting the rotary knob, connecting leads, and safety precautions.

Low Resistance Measurement Procedure

Measurement Steps

Outlines wiring, discharge, and test procedure for low resistance.

Insulation Resistance Measurement

Voltage Selection and Procedure

Details selecting test voltage, wiring, and performing continuous measurement.

Polarization Index Measurement

Instructions for measuring PI using the PI/DAR button and TEST button.

Dielectric Absorption Ratio Measurement

Steps for measuring DAR using the PI/DAR button and TEST button.

Battery Replacement Procedure

Replacement Steps

Provides instructions and safety warnings for replacing batteries.

Maintenance

Cleaning and Servicing

Guidelines for cleaning the instrument housing and professional servicing.

Overview

The UNI-T UT502A is an insulation resistance tester designed for measuring insulation resistance, low resistance, and AC voltage. It features a brand-new design combining massive integrated and digital circuits, offering high accuracy, stable performance, easy operation, and reliability. This instrument is an ideal tool for electric equipment maintenance, testing, and inspection, suitable for insulation materials and various electric equipment like transformers, electric machines, cables, switches, and electrical appliances.

Function Description:

The UT502A primarily measures insulation resistance, low resistance, and AC voltage. It also supports Polarization Index (PI) and Dielectric Absorption Ratio (DAR) measurements, which are crucial for assessing the quality of insulation.

Important Technical Specifications:

Insulation Resistance Measurement:

  • Rated Voltage: 500V, 1000V, 2500V
  • Measurement Range:
    • 500V: 0.00MΩ ~ 5.00GΩ
    • 1000V: 0.00MΩ ~ 5.00GΩ
    • 2500V: 0.00MΩ ~ 20.0GΩ
  • Open Circuit Voltage:
    • 500V: DC 500V +10%
    • 1000V: DC 1000V +10%
    • 2500V: DC 2500V +10%
  • Rated Measurement Current:
    • 500V: 1.00mA ~ 1.10mA (under 500kΩ)
    • 1000V: 1.00mA ~ 1.10mA (under 1MΩ)
    • 2500V: 1.00mA ~ 1.10mA (under 2.5MΩ)
  • Short Circuit Current: Approximately less than 1.8mA
  • Accuracy Range:
    • 0.00MΩ ~ 99.9MΩ: ±(3%+5)
    • 100MΩ ~ 10GΩ: ±(5%+5)
    • 10.0GΩ ~ 20.0GΩ: ±(10%+5)

Polarization Index (PI) / Dielectric Absorption Ratio (DAR) Measurement:

  • PI Measurement: 10min insulation resistance / 1min insulation resistance
    • PI Value > 4: Best
    • 4-2: Good
    • 2-1: Warning
    • < 1: Bad
  • DAR Measurement:
    • 1min insulation resistance / 30s insulation resistance
    • 1min insulation resistance / 15s insulation resistance
    • DAR Value > 1.4: Best
    • 1.25-1.0: Good
    • < 1.0: Bad

Low Resistance Measurement:

  • Open-circuit Voltage: Approximately 5.0V
  • Measurement Range: 0.00 ~ 200Ω
  • Resolution Ratio: 0.01Ω
  • Accuracy: ±(2%+3)Ω

Voltage Measurement (AC):

  • Measurement Range: 30 ~ 750V (50/60Hz)
  • Resolution: 1V
  • Accuracy: ±(2%+3)

General Specifications:

  • Display: LCD, maximum reading 1999
  • Low Battery Indication: "[]" symbol
  • Overload Indication: ">22.0GΩ" for insulation resistance measurement
  • Automatic Range: Yes
  • Unit Display: Displays unit and function simultaneously
  • Automatic Voltage Release: Yes
  • Backlight: For working in dark sites
  • Red Light: For warning
  • Work Condition: 0°C ~ 40°C, relative humidity ≤ 85%
  • Storage Condition: -20°C ~ 60°C, relative humidity ≤ 90% (Altitude: <2000m)
  • Dimension: 150mm (L) x 100mm (W) x 71mm (D)
  • Current Consumption: About 200mA (under maximum 2500V output), about 10mA (under normal condition)
  • Accessories: Test leads, alkaline battery 1.5V (AA battery) x 6, operating manual, carrying case
  • Weight: 0.7kg (including battery)
  • Power: Alkaline battery 1.5V (AA battery) x 6
  • Safety Compliances: Overvoltage CATIII 600V, Pollution Degree 2 as per IEC61010

Usage Features:

  • Rotary Knob: Used to select test voltage (500V/1000V/2500V) for insulation resistance, ACV for AC voltage measurement, and CONTINUITY for low resistance measurement.
  • PI/DAR Button: Initiates Polarization Index and Dielectric Absorption Ratio measurements.
  • ZERO/LIGHT Button: Toggles backlight and resets the display to zero for low resistance measurement.
  • TEST Button: Activates/deactivates insulation and low resistance measurements.
  • Continuous Measurement: The instrument can self-lock to measure continuously after pressing the TEST button, with the test voltage output and the TEST button lighting up. Pressing TEST again unlocks and stops the measurement.
  • Safety Precautions:
    • Always ensure the circuit under test is completely discharged and isolated from the power circuit before measuring resistance.
    • Do not measure circuits with voltage over 750VAC.
    • Avoid testing in flammable places where sparks could cause explosions.
    • Do not operate the instrument if it is wet or if the operator's hand is wet.
    • Do not touch conductive parts of test leads during measurement.
    • Do not open the battery cover during testing.
    • Do not touch the tested line during insulation measurement.
    • If the instrument is damaged or has exposed metal, stop using it immediately.
    • Exercise extreme caution when working under voltages exceeding 33Vrms, 46.7Vacrms, or 70Vdc, as this can cause electric shock.
    • After high resistance measurement, ensure the stored electric charge in the circuit under test is discharged.
  • Low Battery Indication: The "[]" symbol on the LCD indicates when the battery needs to be replaced.
  • Automatic Voltage Release: Automatically discharges stored voltage after measurements.

Maintenance Features:

  • Battery Replacement: When the low battery indicator appears, the 6 x 1.5V AA batteries should be replaced. Ensure the instrument is turned off, test leads are removed, and observe correct polarity during installation. Do not mix old and new batteries.
  • Cleaning: The instrument housing can be cleaned with a soft cloth or sponge dampened with clean water. Avoid submerging the instrument in water. If it gets wet, dry it before storage.
  • Repair and Verification: For verification or repair, the instrument should be delivered to a qualified professional serviceman or designated repairing department.
  • Storage: If the instrument will not be used for a long time, remove the batteries and store it properly. Avoid high temperature, high humidity, inflammable, explosive, or strong electromagnetic field environments.