UNI-T
UPO 3000E&UPO2000E Series Oscilloscope Programming Manual
Return format:
Query return setup data, return data conform to binary data IEEE 488.2 # format.
:SYSTem:LANGuage
Command format:
:SYSTem:LANGuage {
ENGLish | SIMPlifiedchinese | TRADitionalchinese }
:SYSTem:LANGuage?
Functional description:
Set system language.
Return format:
Query return{ ENGLish | SIMPlifiedchinese | TRADitionalchinese }
For example:
:SYSTem:LANGuage ENGL set system language as English
:SYSTem:LANGuage? query return ENGLish
:SYSTem:RTC
Command format:
:SYSTem:RTC <year>,<month>,<day>,<hour>,<minute>,<second>
:SYSTem:RTC?
Functional description:
Set system time.
Return format:
Query return year, month, date, hour, minute and second.
For example:
:SYSTem:RTC 2017,7,7,20,8,8 set system time at 20:08:08 July 7,2017
:SYSTem:RTC? query return 2017,7,7,20,8,8
:SYSTem:CAL
Command format:
:SYSTem:
CAL
Functional description:
Set system self-calibration, the instrument can not communicate when in self-calibration.
:SYSTem:CLEAr
Command format:
:SYSTem:
CLEAr
Functional description:
Empty system storage waveform and setup data.